User manual

51786410X84NXS_V_1_2.DOC
27/58
Connection with the mains
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable Pin International
Brown Live L
Blue Neutral N
Yellow/Green Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
Lighting effects must not be connected to dimming-packs.
OPERATION
After you connected the effect to the mains, the TMH-155 starts running. During the Reset, the motors are
trimmed and the device is ready for use afterwards.
You can control the projectors individually via your DMX-controller. Every DMX-channel has a different
occupation with different features. In order to call up the different features, you first have to open the shutter
(control channel 5, DMX-value 241-255).
Turn the focus-screw next to the objective-lens for adjusting the focus in order to obtain a sharp projection.
Addressing
Each projector occupies 6 channels. To ensure that the control signals are properly directed to each
projector, the projector requires adressing. This is to be done for every single projector by changing the DIP
switches as set out in this table.
The starting address is defined as the first channel from which the TMH-155 will respond to the controller. If
you set, for example, the address to channel 7, the TMH-155 will use the channel 7 to 12 for control.
Please make sure that you don’t have any overlapping channels in order to control each TMH-155 correctly
and independently from any other fixture on the DMX data link. If two, three or more TMH-155 are addressed
similarly, they will work similarly.
Occupation of the DIP-switches: