User manual

00040156.DOC, Version 2.022/26
Occupation of the XLR connection:
If you are using controllers with this occupation, you can connect the DMX output of the controller directly with
the DMX input of the first device in the DMX chain. If you wish to connect DMX controllers with other XLR
outputs, you need to use adapter cables.
Building a serial DMX chain:
Connect the DMX output of the first device in the DMX chain with the DMX input of the next device. Always
connect one output with the input of the next device until all devices are connected.
Caution: At the last fixture, the DMX cable has to be terminated. Plug the terminator with a 120
resistor
between Signal (–) and Signal (+) in the DMX output of the last fixture.
Connection between devices
On the rear panel, there is an NEUTRIK socket (Power Out) for passing on the power supply. Connect the
output with the input (NEUTRIK socket Power In) of the next fixture until all fixtures are connected.
Attention: After every 8 devices the fixtures must have a renewed connection with the power mains.
Connection with the mains
Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable Pin International
Brown Live L
Blue Neutral N
Yellow/Green Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
OPERATION
After you connected the effect to the mains, the STP-10 MKII for 10x GU-10 DMX starts running and the LED
screen lights up.