Operation Manual

~ 34 ~
in their original places and screw the screw tight again.
Switch the device on again and allow it to operate in the ventilation mode for a minimum of 2 hours.
The airco is now completely dry internally.
Take the plug out of the socket, clean the filter, dry it and put it back.
Keep the indoor unit and the outdoor unit connected to each other. Package them in a box together
in order to protect them against dust and moisture and store in a dry place.
CHECK POINTS FOR FAULTY OPERATION
Please check the following:
Fault
Check point
Measure
The device
does not
work
1. Is the main switch switched
off?
2. Power cut?
3.Is the air inlet or outlet (indoor
unit) blocked?
4.The internal fuse may have
burnt out.
5.Is the Voltage too low?
1. Switch the main switch on.
2.Check other equipment
3.Check and remove the blockage if
necessary.
4.Have the device repaired by your
repair service.
5. Check the Voltage of the socket.
The device
will not
re-start
2. Work resumption safety
feature active
2. Wait for three minutes.
The device
does not cool
during
operation
1.Have you set the desired
temperature correctly?
2.Filter blocked by dust?
3. Set correctly.
2. Clean the filter more often.
The device
does not cool
the room
3. Is the room being heated in
some way?
4. The device has insufficient
capacity for the room
5. Switch the heating device off
and close curtains as much as
possible.
6. Choose a device with greater
capacity.
Noise and
vibration
5. Is the device
standing/hanging at an angle
6. Is there a lot of dust in the
filter?
1.Place the device horizontally
and firmly upright.
2. Clean the filter.