12
REINIGING EN ONDERHOUD
Before cleaning or maintenance: always switch off the equipment and unplug it.
Emptying the container
Dry: Bad suction usually points to a full container.
Open the clips, lift the container cover and remove
filter and basket. Empty the container. Types 2070
and 3080 are equipped with a tipping handle and a
tipping bracket, see image.
Wet: Types 2070 and 3080: Disconnect the drainage
hose and empty it into a drain or similar. Remove the
cap off the end of the hose. The container can now
be emptied. In order to remove the final traces of
moisture, tip the container, see image. Type 1240:
Open the clips and lift the container cover. Empty
the container by pouring out any water.
After emptying, replace all parts in original positions.
Cleaning the filter
Clean the filter regularly by thoroughly tapping/brushing it clean. If the filter is very dirty,
pull the fabric bag off the plastic ring and wash it in lukewarm, soapy water. The bag may
also be washed in the washing machine, on max. 30°C. Use a mild washing product and
pull the bag back into shape after washing. Let the filter dry thoroughly before replacing.
Never put it in the tumble dryer!
Never use the device without a filter!
Maintenance:
Keep the body of the device, the filter and accessories clean and regularly check to
ensure no excess air is being sucked in.
Check the cable and plug regularly for damage. Do not use the device if it has a
damaged cable and/or plug but take it to an authorised engineer to be replaced!
Regularly check to ensure no objects are stuck in the suction mouth, hose or pipe.
Remove them if necessary.
Use the device carefully; ensure it does not fall, bump into other objects or become
otherwise damaged.
Store the device in a dry environment.
Never use the device for too long in one go; give it regular opportunities to cool down.
This will extend its life expectancy.
If the device falters, vibrates, makes peculiar noises or emits a burning smell, stop
using it immediately and ask your supplier or service provider to check/repair it.