User Manual

Page 15 EEF54W / EFF54S Upright Cooker User Manual
INSTALLING COOKER - POWER CONNECTIONS
Fitting on a Power Supply Cable
Connecting appropriate power supply ` terminal board/ connector block:
Using a screwdriver ,prize open tabs of the Terminal board cover.
Remove the wire clamp screw.
Fasten the wires beneath the corresponding screw heads, using brass ‘bridge’ for single phase supply.
Fasten cable clamp and close the cover of the terminal board.
The ac power supply should be 220-240 V, 50/60 Hz. For electric cookers, the minimum 32A circuit breaker.
NOTE: To be carried out by a qualified electrician / installer.
WARNING: CONNECT THE POWER CORD MUST BE IN ACCORDANCE
WITH THE INSTRUCTIONS LISTED IN THE TABLE BELOW
Wire cross-
sectional
area (mm2)
Connection
mode
L1 L2 L3 N E
1N ~ Min6 - - Min6 Min6
2N ~ Min2.5 Min2.5 - Min6 Min6
3N ~ Min2.5 Min2.5 Min2.5 Min6 Min6
Connecting the supply cable to the mains
Install an approved circuit breaker with a minimum contact opening of 3 mm, between the appliance and the mains fuse
box .The circuit breaker should be sized according to the load and should comply with current regulations (the earth wire
should not be interrupted by the circuit breaker).
The supply cable should be positioned so that it does not reach a temperature of more than 50° with respect to the
room temperature, anywhere along its length. Before switching fuse ON in meter-box check:
Earth continuity. The electrical safety of this appliance can only be guaranteed if the cooker is correctly installed
and earthed, in compliance with regulations on electrical installations.
The electrical capacity of the system and sockets will support the maximum power of the appliance,
as indicated on the data plate
Go to section “Installing your new cooker”