Installation
NOTES: All dimension lengths for vertical or horizontal runs are measured
from center of the vent pipe.
Venting runs must fall within the limits set by the venting graph
(see Figure 9a).
Figure 8. Retracted Installation using a combination of solid and ex venting. Use
the vent graph to determine your allowable run, then select appropriate
components.
Figure 9. Horizontal ex installation with minimum vertical rise.
Top Vent Venting Runs
Example A: (Unacceptable Installation N.G. and L.P.)
If the vertical dimension from the hearth is 108" and the horizontal run to the wall ange
of the vent termination is 180", this would NOT be an acceptable installation.
Example B: (Acceptable Installation N.G. and L.P.)
If the vertical dimension from the hearth is 54" and the horizontal run to the wall ange
of the vent termination is 78", this would be an acceptable installation.
Example C: (Unacceptable Installation N.G. and L.P.)
If the vertical dimension from the oor of the replace is 90" and the horizontal run to
the wall ange of the vent termination is 108", this would NOT be an acceptable
installation.
Figure 7b. DV 42 ST Top Vent Venting Graph
RHS8
B. Vertical (Through-The-Roof) 5/8 Installations
Vertical rise >12' can be reduced (on applicable models).
Vertical Terminations must be installed:
• minimum 2' (two feet) above the highest point where
vent passes through the roof.
• minimum 6' (six feet) from a mechanical air inlet
• minimum 18" (1 1/2 feet) from a parapet wall.
Maximum vent height is:
• 32 feet above replace.
1 MIN
1 MIN
1 MIN. Both
sides Typical
RHS8 Heat
Shield
Figure 8a. RHS8 Installation. (Install by sliding over vent pipe where it passes through
the combustible construction.
Figure 8b. RHS101 Installation. (Install by sliding over vent pipe where it passes through
the combustible construction.
Framing
Drywall
RHS101 Heat Shield,
Inner Section.
Vent from fireplace
RHS101 Heat Shield,
Outer Section.
Termination
RHS101
19
max
41 min N.G.
54 min L.P.
19”
54”
34”
N.G.
L.P.
41”
B
C
A
Power Vent models, LDVPV47
EDVRSPV58, and EDVWSPV58
to be used within the shaded area of
graph. (See Index of this guide for
applicable Product page).