Installation
Figure 11c. Rear vent, roof mounted venting (one 90° bend).
Section 3-2-2: VENTING COMPONENTS
Select from the following components and associated European Home part
numbers for installation of a Roof Mounted Termination. Use only European
Home Vent Components. Use of non-European Home parts will void the
warranty and may impede operation of the replace.
Support ring
Support plate
32’ max
MEXT Sections
Termination
12”
Max.
Connection and installation of the vent components should adhere to the following:
• Use any combination of rigid and ex pipe as required.
• Flex sections may be stretched up to 50% of their total length. For
example, a 24” section maybe stretched to 36”.
• Connect all vent sections using a minimum of three sheet metal screws on
the outer pipe ue.
• Ensure the pipe ends male to female slide in a minimum of 1½” of
overlap.
• Ensure all runs are supported with a minimum of 3 supports per 10’ of
venting.
• When hanging/ supporting venting, ensure that 1” clearance is
maintained on sides and bottom of vent runs and 2” above horizontal
vent runs to any combustible material.
• Ensure when cutting sections of rigid pipe to maintain integrity of
internal supports.
• Place the springs, supplied with the pipe kit, between the outer and inner
pipes to keep the pipes separate and avoid any possible hot spots.
• European Home recommends the use of a ex section for the nal
pipe connected directly to the replace oering greater exibility of
installation and absorption of movement.
• When penetrating a combustible ceiling, a ceiling restop must be used.
• European Home recommends that all exterior corners and joints be
sealed with exterior caulking, however, we encourage you to consult
your Building Envelope Engineer or Waterproong Consultant for further
recommendations.
A - Termination PVTK-1
B - Flex Sections PFL - 1 (12" f/f Section)
PFL - 18 (18" f/f Section)
PFL - 2 (24" f/f Section)
PFL - 3 (36" f/f Section)
PFL - 4 (48" f/f Section)
PFL - 6 (72" f/f Section)
C - Rigid Sections PXT - 5 (5" f/f Section)
PXT - 12 (12" f/f Section)
PXT - 20 (20" f/f Section) PEXT -
1 (12" f/m Section)
PEXT - 2 (24" f/m Section)
PEXT - 3 (36" f/m Section)
PEXT - 4 (48" f/m Section)
PEXT - 6 (72" f/m Section)
D - Support Ring and
Plate
PSPXT-8
E - Firestop FS-8
F - Roof Flashing PRF-7 (1/12 - 7/12 pt.)
PRF-12 (7/12 - 12/12 pt.)
PVTK1