Owner`s manual

Page 15
DV 42 Indoor Gas Fireplace
Installation
Connection and installation of the vent components should adhere to the
following:
Section 3-3-2: VENTING COMPONENTS
The following components and associated European Home part numbers are
available for installation of a wall mounted termination. Use only European Home
vent components. Use of non-European Home parts will void the warranty and may
impede operation of the replace.
Use any combination of rigid and Flex pipe as required.
Flex sections may be stretched up to 50% of their total length. For example,
a 24” section maybe stretched to 36”.
Connect all vent sections using a minimum of three sheet metal screws on
the outer pipe ue.
Ensure the pipe ends male to female slide in a minimum of 1½” of overlap.
Ensure all runs are supported with a minimum of 3 supports per 10’ of venting.
When hanging/ supporting venting, ensure that 1” clearance is maintained
on sides and bottom of vent runs and 2” above horizontal vent runs to any
combustible material.
Ensure when cutting sections of rigid pipe to maintain integrity of internal
supports.
Place the springs, supplied with the pipe kit, between the outer and inner
pipes to keep the pipes separate and avoid any possible hot spots.
European Home recommends the use of a ex section for the nal pipe
connected directly to the replace oering greater exibility of installation
and absorption of movement.
When penetrating a combustible ceiling, a ceiling restop must be used.
European Home recommends that all exterior corners and joints be sealed
with exterior caulking however we encourage you to consult your Building
Envelope Engineer or Waterproong Consultant for further recommendations.
A - Termination PTO-4 (3" Length)
PTO-4F (3" Length)
B - Frame Kits MSR (Stucco Frame)
MOSR (Stucco Frame)
BSR-4 (4" Brick Frame)
BSR-6 (6" Brick Frame)
C - Flex Sections PFL - 1 (12" f/f Section)
PFL - 18 (18" f/f Section)
PFL - 2 (24" f/f Section)
PFL - 3 (36" f/f Section)
PFL - 4 (48" f/f Section)
PFL - 6 (72" f/f Section)
D - Rigid Sections PXT - 5 (5" f/f Section)
PXT - 12 (12" f/f Section)
PXT - 20 (20" f/f Section)
PEXT - 1 (12" f/m Section) PEXT
- 2 (24" f/m Section)
PEXT - 3 (36" f/m Section)
PEXT - 4 (48" f/m Section)
PEXT - 6 (72" f/m Section)
E - Elbows PEL-90MM (m/m 90º Elbow)
PEL-90FF ( f/f 90º Elbow)
PEL-90FM ( f/m 90º Elbow)
PEL-45FM ( f/m 45º Elbow)