Owner`s manual

Page 25
DV 42 Indoor Gas Fireplace
Maintenance
Troubleshooting: SIT Nova 820
The following is a troubleshooting chart of possible problems:
PROBLEM SOLUTION
Noisy Pilot Flame Locate pilot adjustment screw on gas
control valve. Flame is decreased by turning
adjustment screw clockwise.
Pilot won’t ignite Disconnect remote wires and try to light pilot. If
pilot now works, remote connections are faulty.
Check wiring diagram gure 33.
Main burner will not ignite 1. Check wiring (see gure 33).
2. Check wall switch for proper connection.
Models
DV 42
If your replace still does not operate correctly, consult your dealer or the manufacturer.
Troubleshooting: (IPI System).
The following is a troubleshooting chart of possible problems:
PROBLEM SOLUTION
Pilot won't ignite or spark. - Check the on the batteries on the remote or
the receiver.
- Check the green LED on AC adaptor
-Check the green ground wire under the valve
Main burner will not light. - Check the wiring on the valve as per diagram
Fan not working - Make sure the fan speed control is on.
- 10 minute delay to turn on.