Owner`s manual

Page 6
DV 42 Indoor Gas Fireplace
Installation
Section 2: Framing
1). Frame in the enclosure for the unit with framing materials. The framed opening
for the assembled replace is 42" wide, x 37" high x 22⁄" deep. See Figure 2.
NOTE: When constructing the framed opening, please ensure there is access
to install the gas line when the unit is installed. See Figure 2.
Figure 2. Framing dimensions for straight wall and corner installation.
Clearances
When installing a shelf over the top of the replaces, the following must be maintained:
For rear vent applications, the minimum clearance is 2" from the rear of the
replace to a wall, or any combustible materials, and 10" clearance from the top
of the replace to the underside of any combustible shelf materials.
For top vent applications, the minimum clearance is 2" from the rear of the
replace to a wall, or any combustible materials, and 21" to the underside of
any combustible shelf materials.
Minimum 2" clearance must still be maintained around the vent pipes.
* When sheetrock is not used behind the replace,
framing depth 22⁄" may be reduced by ⁄".
When facing with the Overlay Method the depth
is increased by ½". See Planning Guide for more
information.
Figure 5. Combustible framing for shelf over the replace, top vent.
Figure 4. Combustible framing for rear vent with shelf above the replace.
Figure 3. Combustible framing for top vent, with shelf above replace.
MODEL
Top - Rear vent
Top - Top vent
Back
Sides
Floor
Mantel
DV 42* 10" 21" 2" 1" 0" 6"
22 5/8”
42”
37”
84 7/8”
0" clearance
to corners only
42”
60 5/8”
1” Min
37”
Combustible Header,
with Supplied shield.
Combustible
Shelf
10”
1” Min
L.P. & N.G
33”
REAR VENT
N.G. ONLY
2” Min
12”
Max.
N.G.
37”
Combustible Header,
with Supplied shield.
Combustible
Shelf
10”
REAR VENT
N.G. ONLY
Combustible Header,
with Supplied shield.
Combustible Shelf
40 1/2”
21”
PEL
Short
90 elbow
N.G. & L.P
.
2” Min
37”
Figure 5a. Non-combustible framing for top vent or rear vent, with alcove.
MIN
96”
12”
8”
door
opening
3”
Rear
Vent
Cieling
Floor
Alcove over fireplace
Top Vent
N.G. & L.P.
12”
max.
1”
min.
Non-combustible
header
Min 1”
REAR VENT
N.G ONLY
(Noncombustible
Material ONLY)
Note: Straight through the wall rear vent available on natural