Owner`s manual
Page 8
DV 42 Indoor Gas Fireplace
Installation
Section 3: Venting
Figure 7. Flue cover and collar removal, top vented replace.
Figure 8. Flue cover and collar installation, rear vented replace.
Section 3-1: CONVERTING TO REAR VENT
Use the following instructions to convert a DV 42* for rear vent use:
1. Remove the rear ue cover and gasket (5" and 8") on the ue outlet, as
shown in Figure 7.
2. Next, remove the top ue collars (5" and 8") on the ue outlet, as shown in
Figure 7.
3. Install the (removed) rear ue cover and gasket material, to the top vent outlet.
Fasten the cover with included hardware, as illustrated Figure 8.
4. Install the (5" and 8") collars to the rear vent outlet using the included hardware,
as illustrated Figure 8.
5” Inner Flue Collar
8” Outer Flue Collar
Flue Gasket
Flue Cover Plate
Flue Gasket
Flue Cover Plate
8” Outer Flue Collar
5” Inner Flue Collar
European Home supplies a variety of direct venting and termination options. The
direct vent termination location MUST be selected such that it is the highest point in
the venting assembly. It should also be selected such that it provides the shortest vent
run possible. Should it be impossible to ensure that the termination is the highest
point or to meet the venting guidelines laid out below please contact your European
Home dealer to discuss power venting options.
NOTES FOR PLANNING VENTING:
Venting can originate from the unit through the top or through the rear. Venting can
terminate through the roof or through an exterior wall.
Refer to Appendix A - Termination Locations to ensure the planned termination
location is acceptable.
Once the termination location has been established, refer to the appropriate section
below for installation details. All replaces shipped from the factory are top vent. See
Section 3-1 for converting the unit from top vent to rear vent.