Installation manual

15
CLEARANCES
Element4 Gas Fireplaces EuropeanHome.com
2" (50)
1" (25)
2" (50)
1" (25)
2" (50)
1" (25)
APPLIANCE
GLASS
COMBUSTIBLE MATERIAL
NON-COMBUSTIBLE LINING
11"
(280)
11"
(280)
11"
(280)
APPLIANCE
GLASS
COMBUSTIBLE MATERIAL
2" (50)
2" (50)
2" (50)
APPLIANCE
GLASS
NON-COMBUSTIBLE MATERIAL
WITHIN COMBUSTIBLE AND
NONCOMBUSTIBLE WALLS
Figures 8 through 10 show clearances to
combustible and non-combustible walls.
Figure 8 shows a typical method for
protecting combustible walls while
maintaining close installation dimensions.
The non-combustible lining MUST extend
more than 26/660 mm above the top of
the replace. The lining shall be place no
closer than 1/25 mm to the oor or any
intersecting walls. Air MUST be allowed to
continually circulate around the lining.
Note: The 1/25 mm and the 2”/50 mm air
gaps MUST be maintained.
Figure 9 shows the minimum distance to
combustible materials.
Figure 10 shows the minimum distance to
non-combustible materials.
2”/50 mm
Figure 8 Plan View
Figure 9 Plan View
Figure 10 Plan View
1”/25 mm
2”/50 mm
1”/25 mm
2”/50 mm
2”/50 mm
11”
280 mm
2”
50 mm
11”
280 mm
11”
280 mm
2”
50 mm
1”
25 mm