Installation manual
18
CLEARANCES
Element4 Gas Fireplaces EuropeanHome.com
B
The total area of the convection air outlet(s) depends on the replace model. (See Table 7 on page 47.) The location of the outlet(s)
must allow for the free movement of air and must not allow excessive convection air to build up within the chase. The top of the
outlet(s) must be at least 1”/25 mm down from the ceiling and we recommend no more than 6”/152 mm down.
The minimum distance from the bottom of the appliance to the room ceiling is 72”/1830 mm. See Table 3.
A
TYPICAL CLEARANCE DIAGRAMS
Figure 13.
Minimum Distances
A
Room ceiling to
appliance bottom
72”
1830 mm
B
Room ceiling to top of
Convection Air Outlet
1”
25 mm
Convection
Air Outlet
Table 3