Installation manual
29
VENTING
Element4 Gas Fireplaces    EuropeanHome.com
V
V2
H
V1
Distance "H" = 0 - 3m (min - max)
Distance "V1" = 500mm - 10m (min - max)
Distance "V2" = 500mm - 10m (min - max)
Distance "V" (= V1+V2) = 1m - 11m
 (min - max)
Distance "V" =2x "H" (min)
Distance “H” = 0”/0.0 m minimum to 9’10”/3.0 m maximum
Distance “V1” = 19”/500 mm minimum to 33’10”/10.0 m maximum
Distance “V2” = 19”/500 mm minimum to 33’10”/10.0 m maximum
Distance “V” (V1+V2) = 3’3”/1.0 m minimum to 36’/11.0 m maximum
Distance “V” must be greater than twice the distance of “H”
Subtract 3’3”/1.0 m of maximum height for every 90° elbow up to a maximum 
of four (4) 90° elbows.
Figure 23. Vertical Terminations with 90° elbows
VERTICAL VENT TERMINATIONS WITH 90° ELBOWS