Installation manual

34
ENCLOSING the FIREPLACE
Element4 Gas Fireplaces EuropeanHome.com
THE FRAMING
A safe installation of your Element4 replace requires that four things be clearly understood.
1. Most important, these replaces are NOT zero-clearance replaces. Unlike most others, there is not a metal box around the
Element4 replaces. With no metal box there are no louvers to distract your view of the re. We do, however, want the cooling
advantage of a metal box.
2. This means that your replace enclosure must be made to act the way a metal replace box acts - letting room air in below
and warm air out above. The non-combustible framing cannot interfere with the air ow. The inlets for the room air are part
of the replace and cannot be changed or adjusted. The outlet is part of your enclosure design, is provided by you and MUST
be included. Note: The Convection Air Outlet must be installed in the same room as the replace or a room which ALWAYS ows air
into the room in which the replace is installed. The ow of convection air must NOT be blocked.
3. Since these are not zero-clearance replaces, the clearances and dimensions listed in the CLEARANCES section MUST be
maintained. Only the non-combustible wall board, the mounting brackets and the venting may touch the replace. As
previously stated, non-combustible framing must be used and may be no closer than 2”/50 mm.
4. The controls are not mounted on the replace, they are to be mounted to your framing and below the burner. The controls
are at the end of a 50”/1270 mm line set and are to be mounted to the BDLE4 Access Door, included. The controls must be
located for ease of physical access (gas line, maintenance, etc.) as well as wireless signal (remote control) access. See the
LOCATING AND MOUNTING THE CONTROLS section.
The combination of multiple glass sides and no zero-clearance box makes for a non-typical framing project. As seen in Figures 27-
29, it is easy to build the ‘rough opening’, set the replace then attach the wall. For projects with tight clearances, however, it may
be easier to set the replace rst then frame around it and attach the wall.
In any case, the framing around these replaces must NOT be supported by the replace and the wall material may NOT be
attached to the replace. The framing must be attached to another structure which can bear the entire weight of the enclosing
walls and any attachments to the walls such as TVs, shelves, artwork, etc. The wall material must be attached ONLY to the framing.
COLD CLIMATE INSULATION
For cold climate installations, it is especially important to insulate outside the chase cavity, between studs and under the oor on
which appliance rests, if oor is above ground level. Gas line holes and other openings should be lled with approved restop.
If the replace is being installed on a cement slab in cold climates, a sheet of plywood or a raised platform can be placed
underneath to prevent cold transferring to the replace and into the room. It also helps to tape for maximum air tightness and to
caulk restops.