MAINTENANCE
Element4 Gas Fireplaces EuropeanHome.com
Natural Gas Injector - marked 1200
Propane Gas Injector - marked 320
THERMOCOUPLE MAINTENANCE
The Element4 replaces have two thermocouples; one next to
the pilot ame and one opposite the pilot burner on the other
side of the main burner. The completeness and operation of
both must be checked. A qualied installer must conrm that
the thermocouple is in place and not cracked or damaged.
Figure 67 shows a typical pilot ame engulng the rst ther-
mocouple.
VENT MAINTENANCE
The following venting system inspection by a qualied service
technician is recommended every six months:
1. Inspect for excessive condensation, e.g. water droplets
forming in the inner lining and subsequently dripping out
of the joints. This can cause corrosion in the system.
2. Check for corrosion in areas exposed to the elements.
Where rust spots or holes have appeared, these must be
immediately replaced.
3. Ensure that there is no foreign material in the vents. Survey
by removing the cap and shining a light down the vent.
4. Check all joints and pipes to make sure that nothing has
been disturbed or loosened.
Figure 67
The orice for the main burners is shown in Figure 45. All NG orices are marked 1200, all LP orices are marked 220.
Figure 68
E4-GS-1T-01 Primary Thermocouple
E4-GS-2T95-02 2nd Thermocouple
E4-GS-CM-01 Receiver
E4-GS-PA-01 Pilot Assembly
E4-GS-RC-01 Remote Control
REPLACEMENT PARTS