SPECIFICATIONS and DIMENSIONS
Element4 Gas Fireplaces EuropeanHome.com
APPLIANCE RATINGS
Model
Modore 240
Tenore 240
Gas
Natural
Gas
Propane
Input Maximum Btu/hr 89,100 64,700
Input Minimum Btu/hr 25,900 19,500
Maximum Supply
Pressure
in. w.c. 7 11
kpa 1.74 2.74
Minimum Supply
Pressure
in. w.c. 4 8
kpa 1 2
Manifold Pressure
Maximum
in. w.c. 4.0 10.8
kpa 0.99 2.68
Manifold Pressure
Minimum
in. w.c. 0.4 1.5
kpa 0.1 0.38
Main Burner Injector Marking 1200 (x3) 220 (x3)
Pilot Injector Marking 31.2 27.1
Figure 1 Wall Adapter Connection (arrow)
WALL ADAPTER SPECIFICATIONS
Input Voltage 120V AC
Input Power 9 W
Output Voltage 6V DC
Output Current 500 mA
Size 3.1”H x 2”W x 1.7”D
Output Cord Length 6 Feet
Agency Approvals UL, CSA