Owner`s manual
29
CLEARANCES
Element4 Gas Fireplaces EuropeanHome.com
2" (50)
1" (25)
2" (50)
1" (25)
2" (50)
1" (25)
APPLIANCE
GLASS
COMBUSTIBLE MATERIAL
NON-COMBUSTIBLE LINING
Combustible Material
with a Non-Combustible
Lining
11"
(280)
11"
(280)
11"
(280)
APPLIANCE
GLASS
COMBUSTIBLE MATERIAL
Combustible Material
2" (50)
2" (50)
2" (50)
APPLIANCE
GLASS
NON-COMBUSTIBLE MATERIAL
Non-Combustible
Material
WITHIN COMBUSTIBLE AND
NONCOMBUSTIBLE WALLS
Figures 9 through 11 show clearances to
combustible and non-combustible walls.
Figure 9 shows a typical method for
protecting combustible walls while
maintaining close installation dimensions.
Note: The 1”/25 mm and the 2”/50 mm air
gaps MUST be maintained.
Figure 10 shows the minimum distance to
combustible materials.
Figure 11 shows the minimum distance to
non-combustible materials.
2”/50 mm
Figure 9
Figure 10
Figu re 11
1”/25 mm
2”/50 mm
1”/25 mm
2”/50 mm
2”/50 mm
11”
280 mm
2”
50 mm
11”
280 mm
11”
280 mm
2”
50 mm
1”
25 mm