VENTING
Element4 Gas Fireplaces EuropeanHome.com
As previously noted, restrictors must be tted in some congurations. Use the table below to determine which restrictor may be
needed with your venting conguration. The restrictors are shown in Figure 24.
When Using a Horizontal
(Wall) Termination
When Using a Vertical
(Roof) Termination
When vertical section is up to 39½”/1 m no restrictor required n/a
When vertical section is 39½”/1 m to 9’10”/3 m 35 mm restrictor n/a
When rise is up to 6’6”/2 m n/a 35 mm
When rise is above 6’6”/2 m n/a 60 mm
Note: On Lucius models only, the bottom of the outlet collar is above, and hidden by, a bae. The bae is attached to the inside top of
the replace as shown in Figure 22. The bae must rst be removed before the restrictor can be installed. Remove the eight attachment
bolts. There are two at either end of the bae and four in the middle. The center four are shown in Figure 22.
A restrictor for all replace models installs in the same location; at the very bottom of the outlet collar.
- Attach the appropriate restrictor to the bottom of the outlet collar as shown in Figure 23.
- Re-attach the bae on Lucius models
Table 6. Restrictors by Vent Conguration
INSTALLING A RESTRICTOR
Figure 22
Attachment
bolts (4 of 8)
holding the
Lucius bae
in place.
Figure 23
35 mm 60 mm
Figure 24