Owner`s manual
46
ENCLOSING the FIREPLACE
Element4 Gas Fireplaces EuropeanHome.com
THE FRAMING
A safe installation of your Element4 replace requires that four things be clearly understood.
1. Most important, these replaces are NOT zero-clearance replaces. Unlike most others, there is not a metal box around the
Element4 replaces. With no metal box there are no louvers to distract your view of the re. We do, however, want the cooling
advantage of a metal box.
2. This means that your replace enclosure must be made to act the way a metal replace box acts - letting room air in below
and convection air out above. The non-combustible framing cannot interfere with the air ow. The inlets for the room air are
part of the replace and cannot be changed or adjusted. See Figure 1. The outlet is part of your enclosure design, is provided
by you and MUST be included. Note: The Convection Air Outlet must be installed in the same room as the replace or a room which
ALWAYS ows air into the room in which the replace is installed. The ow of convection air must NOT be blocked.
3. Since these are not zero-clearance replaces, the clearances and dimensions listed in the CLEARANCES section MUST be
maintained. Only the non-combustible wall board, the mounting brackets and the venting may touch the replace. As
previously stated, non-combustible framing must be used and may be no closer than 2”/50 mm.
4. The controls are not mounted on the replace, they are to be mounted to your framing and below the burner. The controls
are at the end of a 50”/1270 mm line set and are to be mounted to the BDLE4 Access Door, included. The controls must be
located for ease of physical access (gas line, maintenance, etc.) as well as wireless signal (remote control) access. See the
LOCATING AND MOUNTING THE CONTROLS section.
The combination of multiple glass sides and no zero-clearance box makes for a non-typical framing project. As seen in Figures 25-
27, it is easy to build the ‘rough opening’, set the replace then attach the wall. For projects with tight clearances, however, it may
be easier to set the replace rst then frame around it and attach the wall.
In any case, the framing around these replaces must NOT be supported by the replace. The framing must be attached to
another structure which can bear the entire weight of the enclosing walls and any attachments to the walls such as TVs, shelves,
artwork, etc. When in doubt, consult with your structural engineer.
Figure 25
Figure 26 Figure 27