Owner`s manual
50
ENCLOSING the FIREPLACE
Element4 Gas Fireplaces EuropeanHome.com
LOCATING THE CONTROLS
The control system for the Element4 replaces consist of three major components; the receiver, the transmitter and the gas
control. The transmitter is the remote control by which you operate the replace. The receiver and the gas control are at one end
of a 50”/1270 mm line set. The other end of the line set is connected to the approximate center of the rebox. As shipped, the line
set is wrapped together and xed beneath the replace. See Figure 24.
When locating the BDLE4 Access Door you must consider three types of access:
1. Line set access. The line set is to be unwrapped which allows the controls to be placed within a radius of
approximately 50”/1270 mm from the center of the replace, as the cable runs. Do not place the controls above the
level of the burner.
2. Physical access. Is the gas valve/receiver accessible for maintenance, etc.?
3. Wireless access. Can the signals from the transmitter (handheld, remote control) get to the receiver, inside the
access door?
MOUNTING THE CONTROLS
The BDLE4 Access Door requires a rough opening of 9⁄”/250 mm high by 6⁄”/175 mm wide. The door should be mounted with
the hinge on the left side. The door can also be mounted with the hinge side down.
- Carefully cut the black tie wraps which hold the line set to the bottom of the replace then carefully unwrap the line set. Lay
the line set out towards the location of the BDLE4 while avoiding kinks and bends with a radius of less than 2”/50 mm. See Figure
34.
- Remove the four bolts holding the white door/frame cover to the frame, separate the frame and cover then mount the BDLE4
frame to the rough opening as shown in Figure 35.
- Replace the white door/frame cover onto the frame and secure it with the four bolts
- Fit the gas control tab into the bracket on the BDLE4 frame then tighten the bolt through the mounting bosses . See Figures 36
and 37
- Set the receiver into the BDLE4 bracket as shown in Figure 38 and connect the wall adapter.
When mounted, the BDLE4 should look like that shown in Figure 39.
COLD CLIMATE INSULATION
For cold climate installations, it is especially important to insulate outside the chase cavity, between studs and under the oor on
which appliance rests, if oor is above ground level. Gas line holes and other openings should be lled with approved restop.
If the replace is being installed on a cement slab in cold climates, a sheet of plywood or a raised platform can be placed
underneath to prevent cold transferring to the replace and into the room. It also helps to tape for maximum air tightness and to
caulk restops.