Installation Instructions
The 25th Anniversary Murano Spa installation must comply with all plumbing and electrical codes. A licensed plumber and
licensed electrician must complete the applicable connections of the pedicure spa.
Electrical Service
110V: 110V, 60 Hz, 5.0 Amp GFCI protected grounded circuit must be used to supply power to the pedicure
spa. (220V if ordered in 220V configuration)
220V: 220V, 50/60 Hz, 5.0 Amp GFCI protected grounded circuit must be used to supply power to the
pedicure spa.
Water Supply
All plumbing connections must conform to local codes.
Water pressure must be 30 to 80 PSI for the sprayer to operate correctly.
Maximum operating water temperature should not exceed 105
°
F (41
°
C) and the maximum supply water
temperature should not exceed 120° F (49° C). (In Massachusetts, the maximum supply water temperature
should not exceed 130
°
F (54
°
C)). Adjust the hot water heater accordingly.
For hot and cold water supply fittings and power drain fittings location, see figure 1 below.
Carefully connect the incoming water supply lines to the appropriate fittings located on the back of the
pedicure spa. Shut-off valves are recommended.
Drain Facilities
The 25th Anniversary Murano Spa comes equipped with a power drain pump. The discharge hose is located at
the back of the 25th Anniversary Murano Spa. The drain hook-up must meet local plumbing codes.
Location/Positioning
Check your Local & State plumbing codes for additional backflow requirements. Any additional requirements
are the responsibility of the owner of the unit.
Backflow Protection Devices for Faucets with Side Spray: Check valves comply with ANSI/ASME
A112.18.3M, A112.18.1M, and CSA B12.