EUROPEAN TOUCH - LIMITED CONDITIONAL* WARRANTY European Touch Holdings, Inc. ("European Touch") conditionally warrants your pedicure spa (the "Pedicure Spa") in accordance with the terms and conditions set forth below for a period of one (1) year commencing on the original date of shipment of the Pedicure Spa to you. The warranty only applies to the Pedicure Spa's original end-user owner or customer (the "Customer").
• • • chrome and plumbing components and will void the limited warranty on those parts. European Touch recommends that you thoroughly read labels and use sanitizing products void of these chemicals. Use of this pedicure spa for functions it was not created for, including, but not limited to, ionic detox or any process that operates by reverse electroplating; this use will destroy plated parts and void the warranty.
OWNERS MANUAL For Elle Spa IMPORTANT INFORMATION Serial Number: Work Order Number: Installed by: Installation Date: The serial number and work order number are located above the water connections at the rear of the unit.
TABLE OF CONTENTS EUROPEAN TOUCH - LIMITED CONDITIONAL* WARRANTY ................................................................ 2 IMPORTANT INFORMATION ............................................................................................................. 4 TABLE OF CONTENTS ................................................................................................................... 5 INTRODUCTION .................................................................................................
INTRODUCTION Thank you for selecting EUROPEAN TOUCH, the leading designer, manufacturer, and marketer of pedicure spas in North America. The Elle Spa (herein referred to as pedicure spa) is an innovative pedicure spa that has been designed to serve you dependably for many years. Please take time to thoroughly read this entire manual before installation and use.
WARNINGS 1. WARNING: RISK OF ELECTRIC SHOCK; do not permit electric appliances (such as a hair dryer, lamp, telephone, radio, or television) within 1.5M (5 feet) of this hydro-massage bathtub. 2. CAUTION: Test the ground fault circuit interrupter protecting this appliance periodically in accordance with the manufacturer’s instructions. 3. Excessive water temperature is dangerous and should be checked before use.
PEDICURE SPA SPECIFICATIONS Hot and cold water supply lines required (hot and cold shut offs may be installed under pedicure spa base) SHIPPING INFORMATION Weight: 225 lbs. (102 kg) - includes spa, carton, pallet (estimated) Shipping Dimensions: 65”L (165cm) x 36” W (84cm) x 53”H (135cm) SPA INFORMATION Overall dimension, seat upright and forward: 59"L (150cm) x 28.25”W (72cm) x 54.50"H (139cm) (manicure trays down) 59"L (150cm) x 45”W (115cm) x "54.
INSTALLATION DIMENSIONS Document ID: 44080001 Rev: A Technical Support: 1-800-626-6912 Page 9 of 28
INSTALLATION INFORMATION MASSAGE CHAIR Item Part Number 1 4416013x(1-5) 2 44130001 3 44021301 4 44010200 5 44130003 6 25132005 7 01130005 Document ID: 44080001 Description Milo Chair (colors vary) Screws SS #6 size, ½ Panhead Elle Mani Tray Mounting Brackets Mani Trays Screw 5/16 – 18 x 3” SS Hex Head Cap Screw Washer M8 8.4MM ID-24MM OD – 1.
INSTALLATION INFORMATION MASSAGE CHAIR Install seat track onto shell base using: • 5/16 -18 x 3” bolt (Qty 4) • 8M flat washer (Qty 8) • 5/16 nut with nylon lock • ½” open end wrenches or sockets Install seat cushion on seat track using: • Wing nuts (Qty 2) Install seat back (this is heavy and may require two people to install) using: • Alignment pins • 3mm allen wrench. Lay the seat back face down on the seat cushion.
INSTALLATION INFORMATION PLUMBING Note: Failure to comply with federal, state or local codes and ordinances will result in warranty being null and void. This pedicure spa installation must comply with all mandatory “state” or “local codes” for all plumbing and electrical codes. A licensed plumber and licensed electrician must make the utility connections to this spa.
INSTALLATION INFORMATION ELECTRICAL ELECTRICAL SERVICE 110V: 110V, 60 Hz, 2.75 Amp GFCI protected grounded circuit must be used to supply power to the pedicure spa. Grounding Instructions WARNING – When using electrical products, basic precautions should always be followed, including the following: 1. DANGER: RISK OF ELECTRIC SHOCK. Connect only to a circuit protected by a ground-fault circuit interrupter. 2. Grounding is required.
Component Reference Pipless jet motor on front wall Drain Plunger . On/Off Motor & Optional Power Drain Water Fill & Sprayer Drain Handle Water Faucet Handle Note: Adjustable Footrest Pad Pressing with finger nails, rather than the pads of fingers, will damage the on/off switch and will not be covered under the warranty DO NOT PLUG OR COVER JET HOLES WITH ANY ITEMS, INCLUDING TOES.
REMOVING AND REPLACING LOCKING CAP Check your state and local regulations for cleaning procedures. Links to your state boards can be found on our web site, at www.europeantouch.com. 1. Place the cap into position and turn clockwise until the locking pin is at the top right corner of the motor mount. 2. To remove cap the use of a tool is required. 3. Insert tool shown in diagram (below) adjacent to locking pin. 4. Gently turn the cap counter-clockwise to remove cap.
OPERATING INSTRUCTIONS JET OPERATION GETTING STARTED 1. Verify the drain control valve is closed. 2. Open the faucet handle and fill tub with water until the water level is 1” above jets. 3. Press on/off membrane switch to start the jets. The jets system must not be turned on when the system is dry, as damage may occur. Such damage is not covered by warranty. While the jet action is in operation, do not use an excessive amount of soap, bath oils or detergent, as high action turbulence often causes foaming.
Operating Instructions FULL BODY MASSAGE SYSTEM All massage functions can be operated using the remote control. On/Off selection turns the massage functions on and off. If an operation is valid the remote will beep once. If an operation is not valid the remote will beep twice. Auto massage will proceed through all the massage functions using a preprogrammed routine covering the back, waist and shoulders.
Warning – To reduce the risk of burning damage, fire, electric shock or bodily harm: 1. Before using the chair, make sure to uncover the back pad and check if there is any damage to the cloth. If any damage is found, stop using immediately and send it to an authorized repair center or call European Touch. 2. This item should only be operated according to the manual. 3. Do not stand on the chair. 4. Unplug the chair when not in use. Close all massage functions before unplugging the chair. 5.
PIPE-FREE SPA CLEANING AND DISINFECTING PROCEDURES Always check with your state board for required cleaning and disinfecting procedures. It is extremely important to clean and disinfect your pedicure spa after each pedicure, after the last pedicure of the day, and once a week for overnight cleaning. Regular cleaning will help keep your pedicure spa in good working condition. Proper and continuous cleaning will kill harmful bacteria and germs that can cause infection.
PEDICURE SPA CLEANING LOG SHEET “Sample” Pedicure Spa # Date Document ID: 44080001 Time Initials Rev: A After Client End of Day Technical Support: 1-800-626-6912 Weekly Page 20 of 28
PEDICURE SPA CLEANING LOG SHEET “Sample” Pedicure Spa # Date Document ID: 44080001 Time Initials Rev: A After Client End of Day Technical Support: 1-800-626-6912 Weekly Page 21 of 28
REPLACEMENT PARTS SPA ASSEMBLY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 4401010X(0-2) 00040100 03010056 03010057 03010058 03010061 03010063 06130070 15130000 15130000 08040022 08070010 25022014 25022014 3004140X(1 -2) 30150001 31041401 06130087 06130088 40020001 30010221 25132013 25132013 12010584 06130026 39040000 39020008 39010020 4401000X(1-3) 08040030 12130120 14040151 06130056 44000001 44130002 44030002 44020001 15130016 39
Document ID: 44080001 Rev: A Technical Support: 1-800-626-6912 Page 23 of 28
1 2 3 4 5 6 7 8 9 - 08040005 - 14010113 - 14010115 - 14010175 - 14040477 - 12020194 - 12010177 - 12130091 - 08010007 Pump PDP 110V DPO 40 Coupler 1” Coupler 1.25” Reducer 0.75 – 0.5” CPVC Cord Power Drain Pump 0.75” Barb x 0.5” MPT Brass 0.75” Clear Braided Hose #10 Hose Clamp PVC FTG Waste Arm 1 1 1 1 1 1 1 1 1 1 2 3 4 5 6 7 8 - 08040001 08010004 08010007 08010002 12010235 06010024 12020192 15140022 Pump PDP 110V Hi-Cap Nipple PVC FTG PDP 882 005 PVC FTG Waste Arm Bushing Reducer 1.25” – 0.
Item Part Number Description 1 4416013x(1-5) Chair (colors vary) 2 44130001 Screws SS #6 size, ½ Panhead 3 44021301 Elle Mani Tray Mounting Brackets 4 44010200 Mani Trays Document ID: 44080001 Rev: A Technical Support: 1-800-626-6912 Qty 1 16 1 1 Page 25 of 28
HISTORY AND NOTES Document ID: 44080001 Rev: A Technical Support: 1-800-626-6912 Page 26 of 28
HISTORY AND NOTES
EUROPEAN TOUCH 8301 W. Parkland Court Milwaukee, WI 53223 Phone Number: Toll Free: Fax: Web Site: Email: 1-414-357-7016 1-800-626-6912 1-414-357-6360 www.europeantouch.com info@europeantouch.