Specifications
Document ID: 44080001 Rev: A Technical Support: 1-800-626-6912 Page 12 of 28
INSTALLATION INFORMATION PLUMBING
Note: Failure to comply with federal, state or local codes and ordinances will result in warranty being null and
void.
This pedicure spa installation must comply with all mandatory “state” or “local codes” for all plumbing and
electrical codes. A licensed plumber and licensed electrician must make the utility connections to this spa.
It is mandatory in some states such as Massachusetts to install additional backflow protection (reverse
backflow) on the Hot and Cold water supply lines. Check valves are standard on the Elle Spa. If a state such
as Massachusetts requires additional protection it is the owners responsibility to comply.
Location and Support
Select a level floor location for installation. The floor structure beneath the pedicure spa must be capable of
supporting the occupied unit. For the seat back to fully recline, the spa base must be mounted at least 25 inches
from the wall as shown below:
WATER SUPPLY
• All plumbing connections must conform to local codes.
• Water pressure must be 30 to 80 PSI for the sprayer to operate correctly.
• Maximum operating water temperature should not exceed 105
°
F (41
°
C) and the maximum supply
water temperature should not exceed
120° F (49° C). (In Massachusetts, the maximum supply
water temperature should not exceed 130
°
F (54
°
C)). Adjust the hot water heater accordingly.
• For hot and cold water supply fittings and power drain fitting locations, see figure 1 below.
• Carefully connect the incoming water supply lines to the appropriate fittings located on the back of the
pedicure spa. Shut-off valves are recommended.
**Note: See local and state codes as to what type of drain connection is required to be made.
Backflow Protection Devices for Faucets with Side Spray: Check valves comply with ANSI/ASME A112.18.3M,
A112.18.1M, and CSA B12
Neoperl
®
DW15GF check valves are
located in the hot and cold water
lines.
The drain line must be a minimum of
3/4” inside diameter from Spa to wall
connection for basin to drain
properly.
Note: Not using the supplied
bulkhead fittings will result in NO
backflow protection. Check your
Local & State plumbing codes for
additional backflow requirements.
Any additional requirements are the
responsibility of the owner of the unit.