DynaGATE 20-30 User manual Rev. 0-7 13 Power supply. How to turn ON/OFF and reset the product
5. Connect the Earth connection terminal (Ref# E below) to an earth point in the installation
6. Connect the Power IN connector (Ref# A and C below) to the DC power source terminals (DC IN+
and DC IN-)
Ref# Description
A Power IN connector: pin A; Positive power supply input (VIN+)
C Power IN connector: pin C; Negative power supply input (VIN-)
E Earth connection terminal
7. Turn ON the DC power source. The DynaGATE 20-30 remains OFF
8. Connect the KEY pin (Ref# B below) to the positive DC power source terminal (DC IN+).
The DynaGATE 20-30 automatically turns ON and the LED 5 turns ON
Ref# Description
B Power IN connector: pin B; Key Input (KEY)
NOTICE
When connecting Pin B to DC IN+, keep it connected for at least 10 seconds.
If you disconnect DC IN+ from Pin B before 10 seconds have passed, the start-up
procedure will not be completed correctly and an immediate and unsafe power down will
occur.
9. To keep the DynaGATE 20-30 turned ON, make sure the KEY Pin remains connected to DC IN+.
71 / 76