User's Manual

Table Of Contents
13 Power supply. How to turn ON/OFF and reset the product DynaGATE 20-30 User manual Rev. 0-7
13.3.1 Note about the Vehicle Ignition Sense
The Vehicle Ignition Sense is a digital input that can be used to read the status of the KEY Pin.
13.4 How to turn OFF the product
There are two ways to turn OFF the DynaGATE 20-30:
l By entering the power OFF command
l By turning OFF the Ignition Key
To turn OFF the DynaGATE 20-30 by entering the power OFF command, complete the following
steps:
1. Login the Administration Console
2. Enter the command poweroff. The system turns OFF
3. Remove the power from the Power IN connector.
To turn OFF the DynaGATE 20-30 by turning OFF the Ignition Key, complete the following steps:
1. Turn OFF the Ignition Key. The system turns OFF after 120 seconds (default condition)
2. Remove the power from the Power IN connector.
13.5 How to reduce the power consumption of the product
To reduce the power consumption of the DynaGATE 20-30, turn OFF the radio interfaces and disable
unnecessary services that contribute to overall system power consumption.
13.6 How to hardware reset the product
To trigger a hardware reset of the DynaGATE 20-30, push the hardware reset pushbutton available in the
Service Panel.