Model: Model: e Thank you for choosing our products.Please read the instructions carefully before installation and keep it available for future maintenance or reference. e Our company reserves the right of final interpretation for this manual. The manual is subject to change without notice.
Important Safeguards Technical specification List of materials Technical drawings Parts identification Installation of ceramic toilet Previous preparation Auto lid open/close Daily maintenance 1.Main unit care and maintenance 2.Spray nozzle maintenance and care Emergency troubleshooting 1.Electricity and water supply cut-off 2.Failure of remote control 3.
IMPORTANT SAFEGUARDS When using electrical products, especially when children are present, basic safety precautions should always be followed, including the following: 1.The appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction. 2.Children being supervised not to play with the appliance. 3.
IMPORTANT SAFETY INSTRUCTIONS /\ CAUTION Indicates that failure to follow the instruction may cause body injury or property damage. 1. Do not install or use the product in wet places as steam room etc. This product must be connected to properly grounded power outlet socket. 2. It is recommended to use water-proof electrical outlet which should be Installed in the place where is not easily got wet. 3. This product should be used with AC electrical current only,load current is at least 15A.
Technical Specification AC 1200W-1400W Minimum water pressure (20L/min. flow). Maximum water pressure 0.8MPa (Hydro static pressure) length is about 1.
different level adjustment S0W Quiet soft-closing device, Auto open and close The seat temperature will automatically lower to level 1 in 10 minutes after using Seat sensor, Temperature sensor, Bimetallic thermostat, Temperature fuse intelligent,often in the off state To avoid disturbance from remote controls by multi-user Toilet will automatically flush as user walks away from bowl Intelligent lid open/close or by remote controller
List of materials Main Unit Remote controller components Sealing Flange Installation Cardboard Installation Manual Warranty Card
Technical drawing 575 The product shape chart is for reference only, and we reserve the right to modify the appearance of the product.
Parts identification Bumper non Cs POWER | £==D ENERGY SAVER | Ss Power indicator Human body sensing window Energy saving indicator Human body sensing window Remote sensing window Rear cleaning button Seat Drying button GE | Power button BCE wt sin? BT Ceramic toilet Flush button Front cleaning button Water discharging— —— Nozzle baffle Drying baffle Half flush button Rear cleaning Full flush button Front cleaning Main unit disassembly button Spray nozzle Deodorization window Remote sensing window
Installation of ceramic toilet 1.Water supply angle valve installation —; 3.Ceramic toilet installation * Draw drain outlet center line on the floor, Install angle valve at proper position on wall according to dimension of toilet. Angle valve “ fine Drain outlet L au, 2.Cardboard installation Align cardboard with the center line of drain outlet; » Draw contour line according to cardboard; » Please mark the position of floor fixing bolts.
» Connect water inlet and angle valve by new hose. Woodworm ME EWE BR REE Note: Recommend strongly to install floor fixing bolt! It can make product more stable to avoid damage of toilet or personal injury because of shifting or turning over by misusing(squat or stand on toilet). » Glue the edge of toilet bottom with glass cement. water inlet Glass Cement | new hose Note: \_ angle valve Please clean the drain outlet; Please make sure ceramic toilet outlet sits perfectly on drain outlet.
Previous preparation Angle valve 7 Indicator light Electric leakage test button Protection switch 1 protection 77 switch CASE 1 NOTE: If it's an electric leakage protection plug,press protection switch, indicator light is on which means there is electricity. Press electric leakage test button prior to usage, protection switch bounces to show that protection function works normally. CASE 2 NOTE: If it's not an electric leakage protection plug, insert power plug into power socket directly. 1.
Auto lid open/close If you purchase the intelligent toilet with auto lid open/close function, the product can achieve the function of auto lid open/close. The factory default of this function Is on closed situation, so please start the auto lid open/close function by using remote controller. 1.When user close to the toilet 1.
Daily maintenance Main unit care and maintenance 1.Shut off power supply at maintenance. 2.Turn the seat upward open, press down the button located on the right side of main unit and pull out the seat. Wipe the stain with a soft damp cloth. 3. Safety self inspection After cleaning, re-connect the toilet with the power supply. Spray nozzle maintenance and care 1.Nozzle self-cleaning Press “nozzle cleaning” button and nozzle will move forward and self-clean. 2.
Emergency Troubleshooting Electricity and water supply cut-off 1. POWER TRUE sms « Manually press button of full/half ush to perform the toilet flushing. Operation pane Put around 8L water into a barrel and ush the bowl of ceramic. Note:Avoid water spilling from bowl.
Failure of remote control When the product is left unused for long time temperate the panels on bidet seat to perform. « Especially in winter season, the water inside the tank should be discharged to avoid freezing. To discharge water 1. Turn off the water supply angle valve 2.Cut off the electricity 3.Discharge water e Slightly press inward the discharging button to discharge water. 2.
The illustration of main unit keys 1. Long press "power" button to enter standby mode; and then quick es press "power" button to restore functional mode. oO; Power | 2. When people sit, press "power" button to stop the function of rear, front cleaning or drying. When no one sits, press "power" button to switch between function mode and power save mode. Press "flush" button to activate full flushing. Press "dry" button, warm wind will come out.
Troubleshooting Guide Problem Cause water supply hose buckling causes block solve the buckling No flushing fill valve is off turn on the fill valve Water supply is cut off Connect water supply and wait for the water Poor flushing Water supply hose buckling causes partial block Solve the buckling Fill valve is not fully turned on Turn on the fill valve fully Filter is dirty and causes block Clean the filter The water is not hot The water temperature is tested on normal temperature level Reset the water tempe
Product Limited Warranty Thank you for choosing R&T product. This product is warranted for one (1) year since the purchasing date for free repair of problems arising out of defects in workmanship while using in accordance with installation manual and usage cations for intended purposes. If the product does not work properly with warranty period, please contact your nearest service center. This certificate must be presented to obtain free service under this warranty.
The picture of product may not entirely consistent with actual appearance and color because of products improvement, please in kind prevail.