Operation Manual

The new programmable radiator thermostat
EURO
tronic
Technology GmbH
Function SPARmatic
Temperatures and control times
Our SPARmatic has two control times
In automatic mode changes between
these two temperaturesaccording to the time
program that has been set.
SPARmatic
Heating time: Heating to comfort temperature
Economy time: Reduction to economy temperature
6:00
9:00
18:00 22:00
Save
Heat
Save
Heat
Save
Comfort temperature (factory setting 21°C)
Economy temperature (factory setting 10°C)
Heating and economy times (2nd heating and
economy time opt.) are specified via the adjustable
time program. SPARmatic has the following
factory pre-set:
1st heating time starts at 06:00
1st economy time starts at 22:00
PROG
After inserting the battery, SPARmatic automatically
requests entry of date and time
Set the year with the thumb wheel
Confirm with the button
Set the month with the thumb wheel
Confirm with the button
Set the day with the thumb wheel
Confirm with the button
Set the hour with the thumb wheel
Confirm with the button
Set the minute with the thumb wheel
Confirm with the button
That's it
PROG
PROG
PROG
PROG
Setting date and time
Display and control elements
1. Heating or economy time in hours
2. Heating or economy temperature or window function
3. Mode AUTO, MANU, or PROG
4. button
Change between AUTO and MANU mode
5. button
Set comfort and economy temperature
6. button
Set the time program
7. Thumb wheel
Adjust temperature and time
AUTO
MANU
AUTO
MANU
PROG
0
6
12
18
24
AUTO
MANU
PROG
21.5o
1
2
6
7
5
4
3
Inserting / replacing batteries
Open the battery compartment
Insert 2 mignon alkaline batteries (Type LR6, AA,
AM3 ) do not use rechargeable batteries!
Ensure that the polarity is correct. Batteries that are
inserted incorrectly, or that leak can destroy the
SPARmatic. The service life of new batteries is
approximately 2 years. It is necessary to change
batteries when the display shows BATT.
After replacing batteries, or after a power supply
interruption, SPARmatic always executes an
automatic adaptation.
However this does not apply for the first
installation.
Dispose of old batteries in accordance with WEEE
guideline 2002/96/EC.
Attention: Do not dispose of batteries in household
waste!!
Installation
SPARmatic
valve bodies. It can be installed without grime and
water spots, because the heating circuit water is not
interrupted.
Loosen the fastening of the old thermostat
head; pull the thermostat head off of the valve.
can be easily mounted on all common
Select an adapter if necessary:
Adapters are required for some valve types.
Prior to mounting, select the appropriate adapter
as shown in the adapter table.
If you require an adapter:
Push the adapter onto the valve and turn it until it
noticeably clicks into place. If the adapter is fitted
with a screw, tighten the adapter with the screw.
The instruction INST is shown in the display.
Since SPARmatic has already moved into the ON
position while date and time were programmed it can
be quickly and easily mounted with a single hand
movement.
Hand-tighten the union nut until the device is firmly
fixed on the valve body. For possible later installations
move the thumb wheel to ON. This facilitates the
installation.
Press any button and will start to adapt.
The device will adapt itself to the stroke of your valve
body. To do this the valve will now be opened and
closed several times to learn the end points.
In some cases this process can take a few minutes.
During this adaptation process ADAPT will be
shown in the display.
SPARmatic
After successful adaptation returns
to normal mode.
Should adaptation become necessary again,
e.g. if your radiator does not cool down in
OFF Position, please press the button
> 2 seconds until adaptation begins.
SPARmatic
Installation
Adapting
PROG
The motor will move to the ON position to facilitate
installation. The instruction INST is shown
in the display.
SPARmatic