User's Manual

72
14.5 Installation of Novell server with IPX protocol
The IPX server for Novell can be used on a Novell Netware network 3.x/4.x/5.x/6.x.
This is the installation procedure:
Connect the SmartKey NET dongle on any parallel port of the network server.
Carry out a login operation as a SUPERVISOR user from any client computer of the network. If, for security
reason, you do not have the password to access as a SUPERVISOR user, contact your network administrator
and ask him to install the software.
Copy the NSKEYSRV.NLM program, supplied with the dongle, in the SYSTEM directory of the SYS volume
of the server. This is an .NLM file (Netware Loadable Module) that must remain in the server's memory.
Example:
COPY A:\NSKEYSRV.NLM X:\SYSTEM
From the server console, edit file AUTOEXEC.NCF with command
LOAD EDIT AUTOEXEC.NCF
or through the system's utility
LOAD INSTALL
Add the following at the bottom of the instruction file for loading the NLM module:
LOAD NSKEYSRV
and save the modifications by exiting the editor. In this way, the NLM module will be automatically loaded in
the memory whenever the server is powered up.
When executing this NLM module for the first time, to avoid powering down and powering up the server, type
the following command on the console:
LOAD NSKEYSRV
After the NLM module has been loaded, a screen is activated, reserved for showing statistics on the use of the
SmartKey dongles. The name of the NLM also appears on this screen, as declared to all Client stations.
In the LOAD instruction for loading the server, one can specify some parameters for configuring it:
-t=<TIMEOUT>
Specifies the time-out in seconds for the protocol.
If this parameter is not specified, a 10 second timeout is
activated. If value 0 is specified, timeout is disabled.
Remember that, for correct use of the dongle in the Novell Netware environment, the IPX protocol must be of the 3.10
or later versions. If it is not, ask your Novell dealer for a free update.
14.6 Installation of Novell server with TCPIP protocol
The TCPIP server for Novell can be used on a Novell Netware 5.x e 6.x system.
This is the installation procedure:
Connect the SmartKey dongle on any parallel port of the network server.
Carry out a login operation as a SUPERVISOR user from any client computer of the network. If, for security reason,
you do not have the password to access as a SUPERVISOR user, contact your network administrator and ask him to
install the software.
Copy the NSKTCPIP.NLM program, supplied with the dongle, in the SYSTEM directory of the SYS volume of the
server. This is an .NLM file (Netware Loadable Module) that must remain in the server's memory.