Operation Manual

BACKGROUND BURNER FOR PELLET BACKGROUND BURNER FOR WALNUT SHELL
BUTTON (P2) - Temperature decrease:
When in programming mode, use this button to modify/decrease the selected menu value. When in WORK/OFF, use instead this button to decrease the room
thermostat temperature value.
BUTTON (P3) - Set/menu:
Use this button to access temperature setting and user and technician parameter menu. After entering the menu, use this button to access the next sub-menu
or set the value and move to the next menu item when in programming mode.
BUTTON (P4) - ON/OFF Unlocking:
Hold this button down for two seconds to manually switch the stove on or off respectively depending on its initial status (OFF or START).
Should have any alarm blocked the stove, press this button to unlock it and subsequently switch it off. After entering the menu or during the programming phase,
use this button to access the lower menu level. Any change is automatically saved
BUTTON (P5) - Heat output decrease:
When in (WORK) mode, use this button to decrease the heat output value. In menu mode, use this button to move to the next menu item or, in programming
mode, to go back to the subsequent sub-menu item. Any change is automatically saved.
BUTTON (P6) - Heat output increase:
When in (WORK) mode, use this button to modify the exchanger speed. In menu mode, use this button to go back to the previous menu item or, in programming
mode, to go back to the previous sub-menu item. Any change is automatically saved.
THE MENU
Press P3 (MENU) button to access the menu.
It includes several items and levels to access settings and control board programming.
The menu items providing access to the technical setting are protected by access code.
Menu M2 – SELECT FUEL
This setting may reserve the fuel type (NOCCIOLINO or PELLET)
Menu M3 – SET CLOCK
Use this function to set current time and date. The control board is equipped with a lithium battery guaranteeing the internal time clock a 3/5 year-long life.
Menu M4 – SET CHRONO
Submenu M4 - 1 ENABLE CHRONO
The programmable thermostat functions can be disabled and enabled.
Submenu M4 - 2 PROGRAM DAY
The daily programmable thermostat functions can be enabled, disabled and set.
It is possible to set two on/off times defined by the times set according to the table below. If the value is set to OFF, the time clock ignores the control.
Selection Meaning Available values
START 1 switching-on time time - OFF
STOP 1 switching-off time time - OFF
START 2 switching-on time time - OFF
STOP 2 switching-off time time - OFF
Submenu M4 - 3 PROGRAM WEEK
The weekly programmable thermostat functions can be enabled, disabled and set.
The weekly programmer consists of 4 independent programmes which can be combined together in different ways.
The weekly programmer can be enabled or disabled.
Moreover, if the time is set to OFF, the time clock ingnores the corresponding control.
N.B.: set the programming carefully in order to avoid overlapping of switching on and/or off times of different programmes on the same day.
Submenu M4 - 4 PROGRAM WEEK-END
The programmable thermostat functions can be enabled, disabled and set for the week-end (days 6 and 7, or Saturday and Sunday).
TIP:
if you still do not know exactly the result you want to obtain, enable only one programme at a time to avoid confusion and unwanted stove switching on and off.
Disable the daily programme (PROGRAM DAY) if you want to use the weekly programme. If you use the weekly programme (PROGRAM WEEK-END) for 1, 2,
3 and 4 programmes, never enable the week-end programme. Always disable the weekly programme (PROGRAM WEEK) before enabling the week-end
programme (PROGRAM WEEK-END).
Menu M5 – SELECT LANGUAGE
Use this function to select one of the languages available.
Menu M6 – MODE STAND-BY
If you select the “MODE STAND-BY” mode, the stove switches off after a period, set by Pr44, during which the room temperature remained at a value higher than
the
SET temperature.
Only if the following condition occurs -
T
SET
< (T
ambiente
- Pr43), it is then possible to switch the stove back on.
Menu M7 – MODE BUZZER
Set it to “OFF” to disable the buzzer
Menu M8 – LOAD INITIAL
Use this function to load pellets for a period of 90 seconds when the stove is switched off and cold. Press P1 button to start and P4 button to stop.
Menu M9 – STATE STOVE
This function displays the current status of all the devices connected to the stove. A few examples are included in the following pages.
Menu M10 – SETTINGS TECHNIC
This menu item is reserved to the stove installer. After entering the password, P1 (increase) and P2 (decrease) buttons allow all the stove working parameters to
be set (KEY ACCESS).
USER FUNCTIONS
Standard functioning of a control board properly installed on a forced air pellet stove is described below with reference to the functions available to users. The
indications listed below refer to a control board fitted with programmable thermostat.
Important: do not inter change the two different bottom of the burner
Choise of the kind of fuel from the main menù.
- Kind of fuel 1 = PELLET (CARICO PELLET)
-
Kind of fuel 2 = NOCCIOLINO (
CARICO NOCCIOLINO
)
18