Operation Manual

PRE LOADING: (available only when the stove is off). There are two pre-load methods available:
NORMAL: hold the P5 key (up) as long as you want the auger tube to work. Press P3 to exit.
AUTO: carries out a pre-load at a time set. Press P3 to exit.
System status: it displays in order: Pellet type settings correction table:
the status of the stove
the fume temperature in °C
fume fan speed (if equipped with encoder) in rpm
the current heat output level
room temperature in °C
auger tube motor speed
exchanger fan speed expressed as a percent
board temperature
flow set
flow measured
Use the P5, P6 keys to scroll through the pages. Press p4 to exit.
PELLET SET: Use the P5 and P6 keys to select the desired load settings and confirm by pressing P4.
GENERAL SETTINGS: the display shows in order:
EXIT: returns to main page.
TIME SETTING: open the time and date settings page. Switch between fields using the P4 (SET) key. Use the P5 and P6 keys to select the desired values.
Note that, thanks to the system calendar, you do not need to set the day of the week. Press P4 to exit.
PROBE ON RADIO (Y/N): enables the room temperature sensor placed inside the handheld remote control. Use the P5 and P6 buttons to enable/disable the
room temperature sensor installed in the handheld remote control. Press P4 to exit. If the communication between the handheld remote control and the stove
is lost, the stove will automatically take the standard room temperature sensor as reference.
LANGUAGE SET: allows you to select the desired language.
LOGS: it displays the events (alarms) log.
SERVICE: it displays information on the stove status.
PELLET LEVEL: enables or disables the pellet level sensor.
ECO-STOP HYS+: positive hysteresis of the room temperature sensor. E.G.: ECO-STOP HYS+ value = 1.0. The stove enters the ECO STOP mode when the
room temperature exceeds the set room temperature by 1.0° C.
ECO-STOP HYS+-: negative hysteresis of the room temperature sensor. E.G.: ECO-STOP HYS+ value = 1.0. The stove resumes its operation once the room
temperature drops below the set room temperature by 1.0 °C.
Programmable thermostat
The programmable thermostat function allows for the programming of the stove automatic switching on and off and of the SET temperature and SET heat output
enabling during the week. To this purpose, you can either opt for the predefined settings or you can make your own ones. You can open the PROGRAMMER SET
menu by holding the P1 key. From the programmable thermostat menu you can make all necessary settings for proper system operation.
Enabling the programmable thermostat
After finding the corresponding menu item, use the P4 (SET) key to open the selection menu. Use the P5 and P6 to enable/disable the option. Press P4 to save
and exit. After enabling the programmable thermostat, you need to switch the stove on by holding the P2 key; it will enter the state previously defined by you for
that particular period of time. If you enable the programmable thermostat when the stove is already running, it will enter the programmed state and level after half
an hour. The stove will carry out the scheduled programme only if switched on. The programmable thermostat is automatically disabled if the stove enters an alarm
condition to prevent the stove from switching on before removing the causes of the alarm. After removing the alarm causes, you will have to enable chrono
(PROGRAM ENABLING) once again.
Maximum heat output level setting
From this menu you can set 3 heat output levels: COMFORT SETTING, NORMAL SETTING, ECONOMY SETTING. To
each of them is assigned a maximum heat output level. Each of them has a settings page.
The TIME SLOT SETTING page displays each day of the week, identified by the field (A3) DAY, each of them divided into
24-hour periods (0, 1, 2, ... 24). Each period is then divided into two half-hours highlighted in this example by the message
(A1) HOURS.
Selecting the functions and the times.
Use the P5 and P6 to scroll through all the hours, days of the week and programming symbols (copy, paste, exit). Press the
P4 (SET) key repeatedly until the notch reaches the desired height. Press the P4 key several times more to set the desired
level (OFF, ECONOMY, NORMAL and COMFORT). Switch to other periods of time using the P5 and P6 keys.
Changing the day of the week.
Use the P5 and P6 keys to select the day of the week. Press P4 (SET) to change the day. All the days of the week are
available for selection. After selecting the desired day, use the P5 and P6 buttons to select the desired period of time and
make the desired settings as previously described. Please note that for each day of the week you can set a significant number
of start-ups, shut-dows and temperature level changes.
To copy the settings made for one of the days of the week, proceed as follows:
use the P5 (next) and P6 (back) keys to scroll through all periods of time until reaching the copy symbol; then, press P4 (SET).
use the P6 (back) key to selected the day of the week and the P4 key to scroll through the days until reaching the day on which you want to paste the previously
copied settings.
press the P5 (next) key until reaching the paste symbol and then press the P4 (SET) key.
Carry out these operations for all the days in which you want to obtain similar results. To exit, use the P5 (next) and P6 (back) keys until you reach the exit symbol
and then press P4 (SET).
Ignition
First connect the stove plug to the mains and load the pellet hopper.
Be careful not to empty the entire bag at once. Perform this operation slowly. The combustion chamber and the burn pot must be cleaned, removing any combustion
residue. Verify that the hopper lid and the door are closed. Failure to do so could cause a malfunction of the stove and subsequent related alarms.
Upon initial start-up ensure that in the burn pot there are no components that will burn (feet bag, instructions, etc.).
Press the P2 key for about 2 seconds (ON/OFF). The following modes are activated in sequence:
Mode CHECK, the system checks if the sensors are correctly installed and functional. If the flow control function is enabled, the system also check the flow
rate sensor. If the calibration procedure has not been carried out, the system reports a relevant error condition.
Mode (Initial warming), the ignition plug and the exhaust blower turn on.
Mode PRE LOADING the exhaust blower and the auger tube run continuously.
Mode Wait pellet loading is interrupted while the exhaust blower remains on together with the ignition plug to facilitate the ignition of the pellet, Fire on mode,
the ignition plug is off and the system checks if the flame is stable enough to generate an increase in the fume temperature of at least 1.5°C/minute. If the
abovementioned condition is met, the stove enters the heat output mode. Otherwise, the system enters the alarm condition due to lack of stability.
Mode Ignition 1, the system switches to the next mode once the fume temperature reaches a set value. If this does not happen within the set time, the system
repeats the mode without loading the pellets. If the conditions for passing to the next mode are still not met, the system enters the start-up failed alarm condition.
setting fume exhaustion correction pellet load correction
0 10% increase 10% decrease
1 8% increase 8% decrease
2 6% increase 6% decrease
3 4% increase 4% decrease
4 2% increase 2% decrease
5 no correction no correction
6 2% decrease 2% increase
7 4% decrease 4% increase
8 6% decrease 6% increase
9 8% decrease 8% increase
10 10% decrease 10% increase
SET TIMES p. 4 F-7
Button (A1) HOURS
Button (A2) NO. ROOM
Button (A3) DAY
Button (A4) COPY
Button (A5) PASTE
Button (A6) EXIT
Button (A7) HEAT OUTPUT
LEVEL OF POWER p. 4 F-7
Livel (A7-a) OFF
Livel (A7-b) ECONOMY
Livel (A7-c) NORMAL
Livel (A7-d) COMFORT
27