& Owner’s Manual WARRANTY ‘RF MODEL’ AUSTRALIAN OWNED POWERED BY AUSTRALIAN MADE FROM IMPORTED & LOCAL COMPONENTS QUALITY & PERFORMANCE - THE LASTING IMPRESSION
Thank you for purchasing an EvaKool fridge freezer. The unit you have chosen has been proudly designed and manufactured in Australia by Australians combining EvaKool’s legendary insulated fibreglass cabinet with world renowned Danfoss compressor technology to produce Australia’s most ingenious, versatile and user friendly 12V/24V fridge freezer combination.
INDEX INSTALLATION..................................................................................... ?? OPERATING INSTRUCTIONS?? • 12 Volt Operation..................................................................... ?? • 240 Volt Operation................................................................... ?? • Important Tips.......................................................................... ?? SELECTION OF FRIDGE/FREEZER OPTIONS.................................... ?? NORMAL OR ECONOMY OPERATION.
INSTALLATION Your EvaKool fridge/freezer is designed to operate from either a 12V or 24V DC power source. It can also operate from a 240V (AC) main supply with the use of a 12V/24V adaptor. When using solar power or power generators ensure that the fridge is connected through a 12V or 24V battery. We recommend the use of anti-surge devices when there is a possibility of ‘spikes’ from the power source. The recommmended mannner to connect your fridge is illustrated below.
Operating INSTRUCTIONS 12 VOLT OPERATION MAINS OPERATION • Connect the military plug end of the fridge lead, supplied with the fridge to the fridge, • The unit can also operate from a 240V mains power source via an EvaKool approved 12V/24V adaptor. • Push cigarette lighter plug into 12V or 24V power outlet. • Connect the military plug end of the adaptor to the fridge and plug the 3 pin plug into the mains.
Selection of FRIDGE/FREEZER OPTIONS Your EvaKool fridge/freezer is uniquely designed to operate as a fridge or freezer or fridge/freezer combo. • When you first start the fridge, remove the insulated internal divider which will allow the air to circulate and hence bring down the temperature in the cabinet quicker • Once the temperature has reached the desired level - refit the divider between the baskets.
NORMAL OR ECONOMY OPERATION Your EvaKool fridge is designed to operate in either normal or economy mode. The normal/economy switch is used to change the speed and capacity of the compressor. eg. In the economy mode the Danfoss BD35 compressor will operate at 2000rpm and is rated at 33 watts. In the normal mode it will operate at 3000rpm and is rated at 45 watts - a 36% increase in capacity.
POWER INLET The military plug (power inlet socket) is notched so that it can only be connected in the correct way. The threaded ring locks locks the plug into place. CIRCUIT BREAKER Your EvaKool is fitted with a 15 amp circuit breaker. breaker will ‘trip’ thereby cutting off all power to the unit. The purpose of the circuit breaker is to protect the compressor should there be: – a direct short to earth; – a power surge or faulty power supply. As a result all the lights on the control panel will go out.
Care & STORAGE DEFROSTING STORAGE • Switch off freezer and open lid. • Open drainage bung to drain waste as fridge defrosts. • A jug of water may be poured over the evaporator plates and inside of the cabinet to assist cleaning. (DO NOT FLOOD OR FILL THE CABINET WITH WATER.) • DO NOT use sharp objects when cleaning and defrosting your EvaKool. Keep your EvaKool clean by wiping both the interior and exterior with a damp cloth using a mild nonabrasive household detergent and dry thoroughly.
Fault Finding GUIDE refer to the TROUBLE SHOOTING FLOW CHART FRIDGE NOT RUNNING? Is the RED light on? • Check power supply. • Check that the fridge lead is plugged in properly, and that no wires are loose. • Check that the temperature dial is not in the ‘OFF’ position. • Check the circuit breaker and press to re-set if necessary. • Try starting in economy and normal positions. • If the red light is on and the fridge is still not running call our Service Department on 07 5492 7777.
SIMPLE TESTS • Fridge does not operate in your vehicle: Run the fridge from a 240 volt power source via an AC adaptor. If the fridge starts and runs then the problem is with your vehicle, either the battery or the wiring. See section on voltage drop (AC adaptor, minimum of 10 amps at 12 volts peak or 5 amps at 24 volts peak). NOTE: The EvaKool AC adaptor model EP24 delivers 24 volts.
Warranty Statement TERMS & CONDITIONS Nexberg Pty. Ltd. trading as EvaKool undertakes to the original purchaser that this product is sold free of defect in materials and/or workmanship under normal use for a period of 5 years subject to the following: EvaKool will repair free of charge or replace at their discretion your EvaKool fridge/freezer if the unit’s failure is as a direct result of faulty workmanship and/or materials.
Service Record Fridge/Freezer As your EvaKool is a portable unit subject to a variety of different operating conditions the purchaser is obliged under this warranty to have the unit regularly inspected by an approved EvaKool service agent. This annual inspection should take no more than 30 minutes and will help ensure that your EvaKool is maintained in peak condition. Please note the cost of this inspection is for the owner’s account.
FOLD AND SEAL WARRANTY CARD MODEL:.................................................................................SERIAL No.:........................ DATE OF PURCHASE:..........................................................INVOICE No.:...................... PURCHASED FROM:........................................................................................................ PURCHASER’S NAME:..................................................................................................... ADDRESS:...
Compressor and fan running 5 Flashes every 4 seconds Over Temperature *Ambient temperature too high *Clean vents/ensure clear air flow over compressor *Fan Fault 4 Flashes every 4 seconds Low Motor Speed *Reduce products/items inside unit *Move so unit is in a low ambient temperature Clean vents/ensure clear air flow over compressor *Fan Fault Electronic Box No Faulty yellow Fault LED Faulty fan.