INSTRUCTION MANUAL FOR MODELS TMDZ50 - 43L DUAL ZONE TMDZ60 - 51L DUAL ZONE TMDZ70 - 62L DUAL ZONE TMDZ80 - 80L DUAL ZONE TMDZ95 - 96L DUAL ZONE
Please read operating manual carefully before using your unit. Please keep manual in a safe place. If lost you can find a digital copy at Evakool.com.au or contact Evakool on 1300 865 665. Contents 1 Safety Instructions 2 Notes on Using the Product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 3 Operation . . .
1 Safety Instructions • Warning: Do not touch exposed cables. • Warning: Do not use fridge if you suspect any connections could be wet. • When using the fridge in the vehicle or boat, please ensure the circuit being used is fused. • Any installation of DC power systems should be handled by a qualified professional. • Make sure the source voltage is correct. The technical data label has the voltage data. • Do not place any electrical devices inside the refrigerator as moisture could harm these devices. 2.
3. Operation • Power: The refrigerator can be powered by a multi-voltage system utilizing either 12/24 Volts or 240 Volts. The electronic module controls the compressor motor and has the added function of a three stage battery protection. When the input voltage drops below the minimum, the compressor will cut out; when the voltage comes back up to the cutin value, the compressor will restart automatically. • Battery Protection: The SECOP compressor requires approximately 11.0 Volts (12 Volt System) or 23.
LED Control Panel SET Button On/Off Switch +/- Buttons LED Display Temperature setting range: -18°C to 10°C. • Plug in the DC or AC power. • Press button for 4 seconds to turn the fridge on. The LED display on the control panel will light up and the interior temperature will be displayed. • Press the SET button once the left bin display will flash, use the and buttons to set the desired temperature for this side.
USB Charging Port and Thermostat Override Switch Thermostat Override Switch USB Charging Outlet USB Port • This USB port can be used to charge small devices. E.g. mobile phones and remote controllers. The socket is rated to 500mA / 5 Volts. Thermostat Override Switch • If your digital thermostat fails and you are unable to set the temperature, turn this switch to Emergency override. This enables the fridge to run until you reach a service centre to replace the faulty component.
4. Cleaning & Maintenance • Clean the appliance inside and out with a clean damp cloth every week. If it is dirty, use sodium bicarbonate dissolved in lukewarm water to clean the unit. • Never use abrasive products, detergents or soap. After washing, rinse with clean water and dry carefully. Do not leave the refrigerator off with food inside or lid closed. • Never clean the appliance under running water.
6. Error Codes Code Reason / Solution ER1 Thermistor is Unplugged - Contact EvaKool ER2 Thermistor is Short Circuited - Contact EvaKool E1 Low Voltage • Please check the source voltage to ensure it is above the cut out. Try lowering the voltage cut out setting to LOW. • The vehicle cabling may be inadequate/unsuitable, please refer to cable specifications table for correct cable thickness (page 5). • Try on a different power source. E2 Fan Issue • Fan is drawing too many Amps (Over 1 Amp).
7. Warranty Statement/Terms & Conditions Nexberg Pty Ltd trading as EvaKool undertakes to the original purchaser that this product is sold free of defect in materials and/or workmanship under normal use for a period of 36 months. Subject to the following: • The warranty period commences from the date of purchase by the original purchaser from an authorised EvaKool dealer. • The Secop compressor in this unit carries a 5 year warranty under normal use.