C-PRO NANO PROGRAMMABLE CONTROLLERS HARDWARE MANUAL CODICE 114CPRNHWE03
C-PRO NANO HARDWARE MANUAL Important Please read these instructions carefully prior to installation and use, and follow all the precautions for installation and electrical connections; keep these instructions with the device for future consultation. The device must be disposed of in accordance with local regulations pertaining to the collection of electrical and electronic appliances.
C-PRO NANO HARDWARE MANUAL Contents 1 INTRODUCTION ........................................................................................................................................ 4 2 COMPONENT AND AUXILIARY NETWORK SYSTEMS.................................................................. 5 3 TECHNICAL CHARACTERISTICS ........................................................................................................ 6 3.1 3.2 3.3 3.4 3.5 3.6 CONNECTIONS .................................
C-PRO NANO HARDWARE MANUAL 1 Introduction The C-PRO NANO family of programmable controllers is the ideal solution for refrigeration, ventilation and air conditioning applications in low complexity situations. Both in terms of regulation operations and the user interface, the controller software is fully programmable, in a simple and intuitive manner, thanks to the use of the UNI-PRO development environment. The C-PRO NANO is manufactured as a panel installation version.
C-PRO NANO HARDWARE MANUAL 2 Component and auxiliary network systems Page 5
C-PRO NANO HARDWARE MANUAL 3 Technical characteristics 3.1 Connections Power supply: The C-PRO NANO is powered by a 12 V AC supply. It may also be powered by a 12 V DC supply; in this case, there is no option for controlling the fan cut-off modules. The maximum length of the power supply connecting cables is 1 m. Analogue input connections: The C-PRO NANO has two analogue inputs for NTC probes and two for NTC probes or for 0/4-20 mA or 0-5V ratiometric transducers.
C-PRO NANO HARDWARE MANUAL Connection with a remote expansion (or an other CAN controller) : The connection between C-PRO NANO and the remote expansion (or other CAN controller) is made using a 2 way cable (better if weaved) plus possible ground.
C-PRO NANO HARDWARE MANUAL 3.2 The C-PRO NANO wiring layout The C-PRO NANO control unit wiring layout is shown below, with the meanings of the inputs and outputs given in the tables. C-PRO NANO wiring diagram Connector 1: Output relay connection Conn. Abbrev. Description C1-1 DO4 Relay No.4, breaker normally open C1-2 DO3 Relay No.3, breaker normally open C1-3 COMMON1 Relays No.s 1,2,3,4 - common C1-4 DO5 Relay No.5, breaker normally open C1-5 DO2 Relay No.2, breaker normally open C1-6 DO1 Relay No.
C-PRO NANO HARDWARE MANUAL Connector 3: Analogue output connector Conn. Abbrev. Description (V+I version) C3-1 AO2 0-10 V DC C3-2 GND Common analogue output C3-3 AO3 4-20 mA Description (I+I version) C3-1 AO2 4-20 mA C3-2 GND Common analogue output C3-3 AO3 4-20 mA Description (V+V version) C3-1 AO2 0-10 V DC C3-2 GND Common analogue output C3-3 AO3 0-10 V DC Connector 4: Connector for low voltage signals Conn. Abbrev.
C-PRO NANO HARDWARE MANUAL 3.3 C-PRO NANO dimensions/installation The mechanical dimensions for the C-PRO NANO are given below; the measurements are in mm (in). For fitting, use the snap-on brackets provided. Dimension A B Minimum 71.0 (2.795) 29.0 (1.141) Typical 71.0 (2.795) 29.0 (1.141) Maximum 71.8 (2.826) 29.8 (1.173) Recommendations for installation: - the panel thickness must not exceed 8 mm (0.314 in) - 95.0 (3.
C-PRO NANO HARDWARE MANUAL 3.
C-PRO NANO HARDWARE MANUAL 3.6 Electrical characteristics CPU Power supply Digital outputs Digital inputs Analogue inputs for NTC probes Analogue inputs for NTC probes or Ratiometric pressure Transducers Microcontroller Program flash memory RAM for data memory EEPROM A/D Voltage Range Frequency Maximum input power Fuse rating Number Type Maximum breaker current at 250 V AC Use all common connectors.
C-PRO NANO HARDWARE MANUAL Fan analogue output UART1 TTL for RS485 serial port (Modbus) Serial output for remote I/O expansion unit and remote keypad Analogue output Voltage + Current, Voltage + Voltage or Current + Current CAN communication Bus Number Type Number Type Physical layer Maximum baud rate Connector Please note: The same connector for the serial port is used for the parameter key and for the interface used for programming the microcontroller flash memory Number Type Physical layer Baud rate
C-PRO NANO HARDWARE MANUAL 4 The C-PRO NANO user interface The display has four red-coloured digits (plus decimal points) and 16 icons of various colours; the keypad has 4 keys.
C-PRO NANO HARDWARE MANUAL Maintenance icon Alarm icon Icon 1 Icon 2 Icon 3 Icon 4 Heating element icon (air conditioning display) Compressor icon (refrigeration display) On-Off icon Keys Set / enter key Number of keys Normal pressing OnOff/esc key Pressed for approx. 3 seconds Normal pressing Up key Down key Esc+enter keys Up+down key Pressed for approx. 3 seconds Normal pressing Secondary function Normal pressing Secondary function Pressed for approx. 3 seconds Pressed for approx.
C-PRO NANO HARDWARE MANUAL 5 C-PRO EXP MICRO I/O expansion units The C-PRO EXP MICRO I/O expansion units allow expansion of the controllers I/O capacity. There are two types of expansion unit, one sealed in a case with 4 DIN modules, and another open mounted on a base with 4 DIN modules.
C-PRO NANO HARDWARE MANUAL 5.1 The C-PRO EXP MICRO wiring layout (IntraBus version) The references to connecting cable lengths reported in chapter 3 are also valid for I/O expansion units. The C-PRO EXP MICRO expansion unit wiring layout is shown below, with the meanings of the inputs and outputs given in the tables. C-PRO EXP MICRO wiring diagram The C-PRO NANO and C-PRO EXP MICRO power supplies must be galvanically isolated from one another. Connector 1: Output relay connection Conn. Abbrev.
C-PRO NANO HARDWARE MANUAL C1-12 COMMON DO6 Relay No.6 - common Connector 2: Connector for low voltage signals Conn. Abbrev. Description C2-1 12 V AC (Power) Device power supply (12 V AC/DC) C2-2 Not connected Not connected C2-3 GND Common analogue and digital inputs C2-4 GND Common analogue and digital inputs C2-5 AI4 Analogue input No. 4 (for NTC probes or for 0/4-20 mA or 0-5V transducers) C2-6 AI3 Analogue input No. 3 (for NTC probes or for 0/4-20 mA or 0-5V transducers) C2-7 AI2 Analogue input No.
C-PRO NANO HARDWARE MANUAL 5.2 C-PRO EXP MICRO dimensions/installation The mechanical dimensions for the C-PRO EXP MICRO are given below; the measurements are in mm (in). 6 Accessories 6.1 User terminals (IntraBus) User terminals allow the control units to be controlled remotely (display and commands). There are two interface types, one panel-mounted, the other wall-mounted. The interface is connected to the special (powered) serial connector of the C-PRO NANO controllers.
C-PRO NANO HARDWARE MANUAL 6.1.1 V LEDi dimensions and installation For panel installation, use the snap-on brackets provided Local panel interface dimensions Connections 3 2 1 GND 12Vdc DATA CI1 Local panel interface connections Connector CI1: Interface connector Conn. Abbrev.
C-PRO NANO HARDWARE MANUAL The user interface has a 7 segment, 4 digit display (plus decimal point), 6 icons, and the user mode is achieved using 4 keys. Display Number of digits Colour 4 Red Summer icon Winter icon Compressor icon Pump icon Defrost icon Alarm icon Colour Colour Colour Colour Colour Colour Red Red Red Red Red Red Keys Set / enter key Number of keys Normal pressing On-Off/esc key Pressed for approx.
C-PRO NANO HARDWARE MANUAL 6.1.2 V WALL dimensions and installation For wall installation, use appropriate rawplugs and screws.
C-PRO NANO HARDWARE MANUAL Connector CI2: Terminal connector powered by a separate transformer Conn. Abbrev.
C-PRO NANO HARDWARE MANUAL The user interface has a 7 segment, 4 digit display (plus decimal point), 6 icons and the user mode is achieved using 4 keys. Display Number of digits Colour 4 Red Led L0 Led L1 Led L2 Led L3 Led L4 Led L5 Colour Colour Colour Colour Colour Colour Red Red Red Red Red Red Keys Set / enter key Number of keys Normal pressing On-Off/esc key Pressed for approx.
C-PRO NANO HARDWARE MANUAL 6.2 Remote User interface (CAN) The user interfaces allow to install a display and keyboard remotely far from the controller . “V-VIEW” user interface (with a alfanumeric 4 x 20 characters LCD display) can be connected to the CAN port of the C-PRO NANO controller. On request a graphic 240 x 128 pixel LCD display (V-GRAPH) user interface is also available . 6.2.
C-PRO NANO HARDWARE MANUAL The following table summarizes the keyboard button meaning: BUTTONS MAIN FUNCTION SECONDARY FUNCTION Predefined as UP Predefined as DOWN Predefined as LEFT Predefined as RIGHT Predefined as ESC Stand-By command Predefined as ENTER 1° programming level command Programmable Alarm reset / identification Programmable Programmable Programmable Programmable Programmable + + + Controller configuration parameters command 2° programming level command 3° programming level command
C-PRO NANO HARDWARE MANUAL 6.2.1.2 V-VIEW wiring layout 6.2.1.3 V-VIEW specifications General specifications Safety standards references EN 60730-1 Purpose of the device Electronic control device connections To be integrated in equipment Plug-in terminal block 5mm pitch for conductors up to 2.
C-PRO NANO HARDWARE MANUAL Type Serial CAN Communication Buzzer LCD Dispay Keyboard CAN V2.0B not optoisolated 2 wires + common, ISO 11898 standard 20K 50K 125K 500K Sconnectable terminals Physical Layer Baud rate (L max. = 10 m) Baud rate (L max. = 5 m) Baud rate (L max. = 2 m) Baud rate (L max. = 1 m) Connector Note: baud rate can be selected by parameter Note: The physical level of the CAN consists of a cable with twisted pair (both shielded and not shielded). The terminator's impedance is 120Ω.
C-PRO NANO HARDWARE MANUAL 6.3 EVDFAN1 cut-off speed regulator The EVDFAN1 is a cut-off speed regulator for controlling single-phase fans (fans with maximum current absorption equal to 5 A). It is ideal for controlling the condensation/evaporation fans on a refrigeration control unit. EVDFAN1 The fan module is available as an open card version, and is mounted on a plastic base suitable for fitting on a DIN rail.
C-PRO NANO HARDWARE MANUAL Terminals 1 and 2: Control input connector (Phoenix pull-out) Conn. Abbrev. Description 1 12 V DC 12 V DC power supply 2 AO1 Impulse cut-off input Terminals 3, 4, 5 and 6: Power connectors (FAST-ON) Conn. Abbrev. 3 LOAD Load 4 LOAD Load (Neutral) 5 LOAD Neutral 230 V AC 6 LOAD Live 230 V AC Description The cut-off module allows the control of single-phase fans with a maximum current equal to 5 A. The fan module live feed must be the same as that feeding the controller.
C-PRO NANO HARDWARE MANUAL 6.4 Accessories for supervision and monitoring These modules allow the conversion of TTL signals to RS485 signals (with or without isolation) for supervision using the MODBUS protocol. The modules connect to the special 6 way AMP micro-match connector on the controller; this connector is shared with the parameter programming key and with the controller flash memory programming tools. 6.4.1 Non-insulated TTL/RS485 interface EVIF20TSX 6.4.
C-PRO NANO HARDWARE MANUAL EVIF21TS7I connections Insulated interface wiring diagram Connector Conn. Abbrev.
C-PRO NANO HARDWARE MANUAL 6.5 Programming accessories 6.5.1 EVKEY programming key The EVKEY programming key allows downloading/uploading parameters (even when the controller is not powered; in this case it is necessary to use the EVPS power supply). The key is connected to the special 6 way AMP micro-match connector, also used for supervision. EVKEY 6.5.
C-PRO NANO HARDWARE MANUAL 7 CAN Connection C-PRO NANO can be connected to other controllers, to expansion modules and to one or more user interfaces using either local or wide CAN serial port. The CAN bus uses the ISO 11898 standard, a balanced two-wire communication very similar to the RS 485 standard. Resistors with a recommended rating of 120-124 ohm have to be fitted at each end of the bus.
C-PRO NANO HARDWARE MANUAL 7.1 Notes on the parameter of the controller relative to the CAN net configuration To log on the controller parameters configuration procedure relative to the analogic output act in the following way : Both for the remote or built-in user interface : 1. Ensure that the controller and the user interface are both switched on and no utilization is connected with the analogic output 2.
C-PRO NANO HARDWARE MANUAL The main parameters of the CAN net are the following : • • • • “My Node” (represents the data sender ID ) “Network Node” (represents the receiver ID) Baud rate (represent the data transmissions speed; initially it can be useful to let this value set at “Auto”; in this way the device will try to connect a few time with different speed) Master (represents network operation) when instrument is set as master it checks device network to find Devices presence.
C-PRO NANO HARDWARE MANUAL C-PRO NANO hardware manual. Version 1.03 January 2009. CODE 114CPRNHWE03. File 114CPRNHWE03.pdf. This document is the exclusive property of Evco, whereby any reproduction or distribution is strictly forbidden, unless expressly directly authorised by Evco. Evco assume no responsibility in relation to the characteristics, technical data and any possible errors reported in this document or deriving from the use of the same.
HEAD OFFICE Evco Via Mezzaterra 6, 32036 Sedico Belluno ITALY Tel: 0437-852468 Fax: 0437-83648 info@evco.it www.evco.it OVERSEAS OFFICES Control France 155 Rue Roger Salengro, 92370 Chaville Paris FRANCE Tel: 0033-1-41159740 Fax: 0033-1-41159739 control.france@wanadoo.fr Evco Latina Larrea, 390 San Isidoro, 1609 Buenos Aires ARGENTINA Tel: 0054-11-47351031 Tel: 0054-11-47351031 evcolatina@anykasrl.com.