Installer manual Owner's manual

EVCO S.p.A. EVDRIVE03 | User manual ver. 3.4 | Code 144EPDE344
page 44 of 70
Par. Min. Mas. Unità Default Menu Probe settings: offset
OfsTs -10.0 10.0 K 0.0 User suction temperature offset
OfsTe -10.0 10.0 K 0.0 User
suction pressure (converted into
temperature) offset
Par. Min. Mas. Unità Default Menu Communication settings
Mb0a 1 247 - - - - 1 Manufact. MODBUS RS-485 port address
Mb0p 0 2 - - - - 2 Manufact.
MODBUS RS-485 port parity
0 = none
1 = odd
2 = even
Mb0b 0 4 - - - - 3 Manufact.
MODBUS RS-485 port baud rate
0 = 1,200
1 = 2,400
2 = 4,800
3 = 9,600
4 = 19,200
Mb0s 0 1 - - - - 0 Manufact.
MODBUS RS-485 port stop bit
0 = 1 bit
1 = 2 bit
Mb1a 1 1 - - - - 1 Manufact. MODBUS prog port address
Mb1p 2 2 - - - - 2 Manufact.
MODBUS prog port parity
0 = none
1 = odd
2 = even
Mb1b 4 4 - - - - 4 Manufact.
MODBUS prog port baud rate
0 = 1,200
1 = 2,400
2 = 4,800
3 = 9,600
4 = 19,200
Mb1s 0 0 - - - - 0 Manufact.
MODBUS prog port stop bit
0 = 1 bit
1 = 2 bit
CANn 1 127 - - - - 11 Manufact. CAN node address