EVCO S.p.A. EVBOX1 | Installation guide ver. 1.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 Important Read this document thoroughly before installation and before use of the device and follow all recommendations; keep this document with the device for future consultation. Only use the device in the way described in this document; do not use the same as a safety device. Disposal The device must be disposed of in compliance with local standards regarding the collection of electric and electronic equipment.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 7 Index 1 Introduction .................................................... 4 1.2 Summary table of available models, their main characteristics and purchase codes ................... 5 2 DESCRIPTION ................................................. 8 2.1 Outward appearance description ........................ 8 2.2 Interior description ........................................ 10 3 DIMENSIONS AND INSTALLATION ..................
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 1 INTRODUCTION 1.1 Introduction EVBOX1 is a line of front mounted electrical boards for the management of cold rooms with single-phase compressor. The user interface comprises a large custom display (with decimal point and function icons), six keys, and has a guaranteed IP65 protection grade front part. The boards are equipped with two 30A res.
EVCO S.p.A. 1.2 EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 Summary table of available models, their main characteristics and purchase codes EVB1204 EVB1214 EVB1206 EVB1216 EVB1226 EVB1236 EVB1246 EVB1256 EVB1204 EVB1214 EVB1206 EVB1216 EVB1226 EVB1236 EVB1246 EVB1256 The following table contains a description of the available models.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 load 5 (default to condenser fan) (3) 8A 8A 8A 8A 8A 8A load 6 (default to alarm ) (3) 8A 8A 8A 8A 8A 8A • • • • • • Communication ports RS-485 MODBUS for other EVCO products • • Other characteristics clock • alarm buzzer • • • • • three-phase defrost elements management • • • • • integrated driver for unipolar stepper electronic expansion valves.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 EVB1256N9D (2) EVB1246N9D (2) EVB1216N9D (2) EVB1216N9M (1) EVB1216N9 EVB1206N9D (2) EVB1206N9M (1) EVB1206N9 Switchboards for single-phase cold rooms (3) EVB1204N9 The following tables show the purchase codes. Notes (2) with differential magneto-thermal circuit breaker (3) also available in version with direct loads connection (add “XXC” after “9” or “XC” after “M” and “D” to the purchase code).
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 2 DESCRIPTION 2.1 Outward appearance description The following drawing shows the outward appearance of the devices.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 12 settings key, hereinafter also "SET" key 13 decrease key, hereinafter also "DOWN" key 14 seal 15 if present, magneto-thermal switch or differential magneto-thermal circuit breaker 16 front shell 17 back shell For additional information, please refer to the following chapters.
EVCO S.p.A. 2.2 EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 Interior description To access the interior of the devices, proceed as follows (numbers in parentheses refer to the part number shown in the tables in paragraph 2.1 “Outward appearance description"): 1. Open the access door of the magneto-thermal switch or differential magneto-thermal circuit breaker (1) using the relevant 2.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 if present, K5 digital output (can be set through a configuration parameter to demister heating elements, auxiliary, alarms, 31 door resistors, neutral area operation resistors, condenser fan, compressor 2, defrosting 2, evaporator fan 2, pump down valve, on/stand-by or man in cold room; manufacturer default is condenser fan).
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 3 DIMENSIONS AND INSTALLATION 3.1 Dimensions The following drawing shows the measurements of the devices, in mm (in). 3.2 Installation The unit is designed to be wall mounted, with bolts and fastening screws (not supplied). To install the devices, proceed as follows (numbers in parentheses refer to the part number shown in the tables in chapter 2 "DESCRIPTION"): 1.
EVCO S.p.A. 3.3 - EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 Installation warnings make sure that the device work conditions (temperature of use, humidity, etc.) lie within the limits indicated; see chapter “TECHNICAL DATA” - do not install the device near to any heat sources (heating elements, hot air ducts etc.), equipment containing powerful magnets (large diffusers, etc.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 4 ELECTRIC CONNECTION 4.
EVCO S.p.A. 4.2 EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 Electric connection for models EVB1204 and EVB1214 The following drawing shows the electric connections for the EVB1204 and EVB1214 models.
EVCO S.p.A. 4.3 EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 Electric connection for models EVB1206 and EVB1216 The following drawing shows the electric connections for the EVB1206 and EVB1216 models.
EVCO S.p.A. 4.4 EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 Electric connection for models EVB1226 and EVB1236 The following drawing shows the electric connections for the EVB1226 and EVB1236 models.
EVCO S.p.A. 4.5 EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 Electric connection for models EVB1246 and EVB1256 The following drawing shows the electric connections for the EVB1246 and EVB1256 models.
EVCO S.p.A. 4.6 EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 Electric connection for models with direct loads connection (example for EVB1216N9XXC) The following drawing shows the electric connections for models with direct loads connection (example EVB1216N9XXC).
EVCO S.p.A. 4.7 EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 Electric connection for models with magneto-thermal switch or differential magneto-thermal circuit breaker (example for EVB1256N9D) The following drawing shows the electric connections for models with magneto-thermal switch or differential magneto-thermal circuit breaker (example EVB1256N9D).
EVCO S.p.A. 4.8 EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 Insertion of the RS-485 MODBUS port termination resistor To reduce reflections on the signal transmitted through the cables connecting the devices to a RS-485 network it is necessary to insert the termination resistor of the first and last elements of the network. To insert the termination resistor place the jumper as shown in the following drawing. 4.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 5 FIRST USE 5.1 First use Operate as follows: Install the device as described in chapter "DIMENSIONS AND INSTALLATION" , following in particular the instructions of 1. paragraph “Installation warnings”. 2.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 6 USER INTERFACE 6.1 Preliminary notes Operating Statuses: - “on” state (the device is powered and is on: the - “stand-by” status (the device is powered but is regulators can be switched on) switched off via software: the regulators are switched off; the possibility to turn the room light or the auxiliary output on/off manually depends on parameter u2) - the “off” status (the device is not powered).
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 The following table shows the correspondence between the labels and the magnitudes displayed. LABEL Pb1 MAGNITUDE room/inflowing air temperature; see also parameter P4 Pb2 evaporator temperature Pb3 auxiliary temperature; see also parameter P4 Pb4 if present, vapour pressure Pb5 if present, evaporation temperature Pb6 CPT temperature; see also parameter P4 4. Press and release the key “SET”. To exit the procedure: 5.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 During the "rapid cooling" function the work set point is decreased by the temperature set with the r5 parameter; the function runs for the span of time set with the r6 parameter. During the "rapid cooling" function the defrosting function is never activated; if the defrosting interval expires while the rapid cooling function is in progress, the defrosting shall be activated at the end of the cooling. 6.
EVCO S.p.A. 2. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 Keep the "AUXILIARY" key pressed for 2 s: the "AUX1" and/or "AUX2" LEDs shall light up and the heating elements be turned turned on, both for the length of time set with the parameter u6. The demister heating elements cannot be turned off in manual mode (that is to say, before the time set with the parameter u6 has expired). 6.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 The following table shows the correspondence between the labels and the magnitudes displayed. LABEL SH MAGNITUDE instant superheating POS percentage (required) valve open POr percentage (instant) valve open 4. Press and release the key “SET”. To exit the procedure: 5. Press and release the key “SET” or do not operate for 60 sec. 6.
EVCO S.p.A. - EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 set the working set point (with the procedure described in paragraph “Setting the working set point”). The operations cause the display of the label “Loc” for 1 s. To unlock the keyboard: 3. Hold the “DOWN” key and the “ON/STAND-BY” key for 1 s: the display will show the message “UnL” for 1 s. 6.12 Silencing the buzzer To silence the buzzer, proceed as follows: 1. Make sure no procedures are in progress. 2.
EVCO S.p.A. 7 EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 OPERATION HIGH WITH LOW RELATIVE OR HUMIDITY PERCENTAGES (ONLY IF THE F0 PARAMETER IS SET TO 5) 7.1 Preliminary notes During operation with a low relative humidity percentage, the evaporator fan shall be turned on if the compressor is on, and shall turn on cyclically if the compressor is off (the F4 parameter determines the duration of the off phase of the fan and the F5 parameter determines the on phase).
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 8 “ENERGY SAVING” FUNCTION 10 “HACCP” FUNCTION 8.1 Preliminary notes 10.
EVCO S.p.A. 10.2 EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 Display of HACCP alarm information To begin the procedure: 1. Make sure that the keyboard is not locked and that no procedure is in progress. 2. Hold the key “DOWN” for 1 s: the display will show the first label available. 3. Press and release the "UP" or "DOWN" key to select “LS”. 4. Press and release the “SET” key: in the models without a clock the 4.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 dur the display is about to show the alarm duration h01 the alarm lasted for 1 hour (continue...) n15 the alarm lasted 1 hour and 15 min code the alarm selected the displays each piece of information for 1 s. To exit the information sequence: 7. Press and release the “ON/STAND-BY”: the display will show the alarm selected. To exit the procedure: 8. Exit the information sequence. 9.
EVCO S.p.A. 11 EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 COMPRESSOR OPERATING HOURS COUNT 11.1 Preliminary notes The device can memorise up to 999 comp. operating hours. The parameter C10 establishes the number of operating hours is higher than the limit at which the need for maintenance is signalled. 11.2 Display of Compressor Operation Hours To display the compressor operation hours, proceed as follows: 1.
EVCO S.p.A. 11.3 EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 Cancelling the compressor operation hours To cancel the compressor operation hours, proceed as follows: 1. Make sure that the keyboard is not locked and that no procedure is in progress. 2. Hold the key “DOWN” for 1 s: the display will show the first label available. 3. Press and release the "UP" or "DOWN" key to select “rCH”. 4. Press and release the “SET” key. 5.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 12 SETTINGS 12.1 Setting the date, time and day of the week (only in the models with clock) The date can be set in the day-month-year format; the time in the hours-minutes format (24 h). To access the procedure: 1. Make sure that the keyboard is not locked and that no procedure is in progress. 2.
EVCO S.p.A. 15. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 Press and release the key or the key within 15 sec to set: 16. - “Mon” (Monday) - “tuE” (Tuesday) - “UEd” (Wednesday) - “thu” (Thursday) - “Fri” (Friday) - “SAt” (Saturday) - “Sun” (Sunday). Press and release the “SET”: the "clock" LED shall turn off, and then the device shall exit the procedure. To exit the procedure before the operation is complete: 17. Do not operate for 60 sec (any changes will be saved).
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 To select a parameter: 7. Press and release the “UP” key or the “DOWN” key. To set a parameter: 8. Press and release the “SET” key. 9. Press and release the “UP” or “DOWN” key within 15 sec. 10. Press and release the “SET” key and do not operate for 15 s. To exit the procedure: 11.
EVCO S.p.A. 12.5 EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 List of configuration parameters EVB1204 EVB1214 EVB1206 EVB1216 EVB1226 EVB1236 EVB1246 EVB1256 -18.0 -18.0 -18.0 -18.0 -18.0 -18.0 -18.0 -18.0 EVB1204 EVB1214 EVB1206 EVB1216 EVB1226 EVB1236 EVB1246 EVB1256 The following table shows the meaning of the configuration parameters of the devices. 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 PARAM. MIN. MAX. M.U. SP r1 r2 °C/°F (1) PARAM. MIN. MAX. M.U.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 percentage of the temperature detected by the inlet air P7 0 100 % 50 50 50 50 50 50 50 50 for the calculation of the CPT temperature (only ifP4 = 4) -99.9 99.9 PARAM. MIN. MAX. 5 5 5 bar g / not not not not not not PSI g avail. avail. avail. avail. avail. avail. bar g / not not not not not not PSI g avail. avail. avail. avail. avail. avail. M.U.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 r4 0.0 99.0 °C/°F (1) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 r5 0.0 99.0 °C/°F (1) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 r6 0 240 min 30 30 30 30 30 30 30 30 r12 0 1 ---- 1 1 1 1 1 1 1 1 working set point increase during the “energy saving" function; see also i5, i10, i15, H01...
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 h06 0 999 s h07 1 250 s h08 -1 100 % not not not not not not avail. avail. avail. avail. avail. avail. not not not not not not avail. avail. avail. avail. avail. avail. not not not not not not avail. avail. avail. avail. avail. avail.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 kind of refrigerat gas h15 0 7 ---- not not not not not not avail. avail. avail. avail. avail. avail. 0 0 0 = R-22 1 = R-404A 2 = R-507A 3 = R-744 4 = R-290 5 = R-717 6 = R1270 7 = R-407F kind of electronic expansion valve h16 h17 0 0 4 100 h18 0 490 h19 0 250 h20 25 999 ---- not not not not not not avail. avail. avail. avail. avail. avail.
240 min EVB1256 0 EVB1246 C0 EVB1236 M.U. EVB1226 MAX. EVB1216 MIN. EVB1206 PARAM. EVB1214 EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 EVB1204 EVCO S.p.A.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.
99 h EVB1256 0 EVB1246 d0 EVB1236 M.U. EVB1226 MAX. EVB1216 MIN. EVB1206 PARAM. EVB1214 EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 EVB1204 EVCO S.p.A.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.
EVB1256 EVB1246 EVB1236 EVB1226 M.U. EVB1216 MAX. EVB1206 MIN. EVB1214 PARAM. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 EVB1204 EVCO S.p.A. TEMPERATURE ALARMS temperature associated with the minimum temperature A0 A1 0 -99.0 1 99.0 ---- °C/°F (1) 0 0 0 0 0 0 0 0 alarm (code “AL”) 0 = room temperature or CPT temperature 1 = evaporator temperature (20) temperature -10.0 -10.0 -10.0 -10.0 -10.0 -10.0 -10.0 -10.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 A7 0 240 min 15 15 15 15 15 15 15 15 A8 0 240 min 15 15 15 15 15 15 15 15 A9 0 240 min 15 15 15 15 15 15 15 15 temperature alarm delay (code “AL” and code “AH”) delay in maximum temperature alarm (code “AH”) from the conclusion of evaporator fan standstill (21) delay in maximum temperature alarm (code “AH”) following the deactivation of the door micro switch input (22) A10 0 240 A11 0.
EVB1256 EVB1246 EVB1236 EVB1226 M.U. EVB1216 MAX. EVB1206 MIN. EVB1214 PARAM. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 EVB1204 EVCO S.p.A.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 F8 0.1 (5) 15.0 F9 0 240 F11 0.0 99.0 °C/°F (1) s °C/°F (1) 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 0 0 0 0 0 0 0 0 F1 differential delay in the switching off of evaporator fan following the switching off of the compressor (only if F0 = 2, 4 and 5) temperature of the condenser above which the condenser 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.
EVB1256 EVB1246 EVB1236 EVB1226 M.U. EVB1216 MAX. EVB1206 MIN. EVB1214 PARAM. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 EVB1204 EVCO S.p.A.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.
EVB1256 EVB1246 EVB1236 EVB1226 M.U. EVB1216 MAX. EVB1206 MIN. EVB1214 PARAM. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 EVB1204 EVCO S.p.A.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 activation of room light switch on/off (in models EVB1204 and EVB1214 only if u1 = 0) or of the auxiliary output (in u2 0 1 ---- 0 0 0 0 0 0 0 0 models EVB1204 and EVB1214 only if u1 = 2, in the remaining models only if u1 and/or u11 = 2) in manual mode with the device turned off (40).
EVCO S.p.A. u9 EVBOX1 | Installation guide ver. 1.
1 not avail. EVB1256 1 EVB1256 not avail. EVB1246 M.U. 1 EVB1246 MAX. not avail. EVB1236 MIN. 1 EVB1236 PARAM. not avail. EVB1226 ---- EVB1226 1 EVB1216 0 EVB1216 Hr0 EVB1206 M.U. EVB1206 MAX. EVB1214 MIN. EVB1204 PARAM. EVB1214 EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 EVB1204 EVCO S.p.A.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 H06 0 24 h H07 0 23 h H08 0 24 h H09 0 23 h H10 0 24 h H11 0 23 h H12 0 24 h H13 0 23 h H14 0 24 h not avail. not avail. not avail. not avail. not avail. not avail. not avail. not avail. not avail. 0 0 0 0 0 0 0 0 0 not avail. not avail. not avail. not avail. not avail. not avail. not avail. not avail. not avail. 0 0 0 0 0 0 0 0 0 not avail. not avail. not avail.
h-- h Hd2 h0 h-- h Hd3 Hd4 h0 h0 h-- h-- h h Hd5 h0 h-- h Hd6 h0 h-- h not avail. not avail. not avail. not avail. not avail. not avail. h-- h-- h-- h-- h-- h-- not avail. not avail. not avail. not avail. not avail. not avail. h-- h-- h-- h-- h-- h-- not avail. not avail. not avail. not avail. not avail. not avail. page 72 of 92 h-- h-- h-- h-- h-- h-- not avail. not avail. not avail. not avail. not avail. not avail.
247 ---- EVB1256 1 EVB1246 LA EVB1236 M.U. EVB1226 MAX. EVB1216 MIN. EVB1206 PARAM. EVB1214 EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 EVB1204 EVCO S.p.A. 247 247 247 247 247 247 247 247 RS-485 MODBUS device address baud rate Lb 0 3 ---- 2 2 2 2 2 2 2 2 0 = 2.400 baud 1 = 4.800 baud 2 = 9.600 baud 3 = 19.
EVCO S.p.A. (7) EVBOX1 | Installation guide ver. 1.
EVCO S.p.A. (30) EVBOX1 | Installation guide ver. 1.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 13 WARNING LIGHTS AND DIRECTIONS 13.1 Signals The following table shows the meaning of the LED warning lights of the device.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 Alarm LED light If the LED is on: - an alarm is in progress If the LED is flashing: - 13.2 compressor maintenance is required; see parameter C10 Signal Descriptions/Explanations The following table shows the meaning of the signal codes of the device. CODE Loc ---- MEANING - the keyboard is blocked; see paragraph 6.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 14 ALARMS 14.1 Alarms The following table shows the meaning of the alarm codes of the device.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 Condenser overheated alarm Solutions: COH - check the condenser temperature; see parameter C6 Main consequences: - the alarm output will be activated (provided that parameter u1 and/or parameter u11 is set at 3) - the condenser fan will be on (only if parameter u1 and/or parameter u11 is set at 6) Compressor shut down alarm.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 15 ERRORS 15.1 Errors The following table shows the meaning of the error codes of the device.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 16 ACCESSORIES 16.1 Non opto-isolated RS-485/USB serial interface EVIF20SUXI 16.1.1 Preliminary notes The interface makes it possible to connect the device to the Parameters Manager set-up software system. 16.2 Data recorder EVUSBREC01 16.2.1 Preliminary notes The device records the board data and their download (via USB in a CSV file format). 16.3 USB cover for panel installation 0812000002 16.3.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 16.4 0810500018/0810500020 connection cable 16.4.1 Preliminary notes The cables can be used to connect the USB cover for panel installation 0812000002 to the EVUSBREC01 data recorder. The 0810500018 cable is 2.0 m long; the 0810500020 cable is 0.5 m long.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 17 TECHNICAL DATA 17.1 Technical data Purpose of the command device: operating command device. Construction of the command device: built-in electronic device. Container: grey self-extinguishing. Heat and fire protection class: D. Dimensions: 262.0 x 179.0 x 95.6 mm (10.314 x 7.047 x 3.763 in; L x H x D). Method of mounting the command device: wall mounted, with bolts and fastening screws. Shell protection grade: IP65.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 Humidity for use: from 10 to 90 % relative humidity without condensate. Command device pollution situation: 2. Height at which it is used: from 0 to 2,000 m (from 0 to 6,591 ft). Height at which it can be transported: from 0 to 3,048 m (from 0 to 10,000 ft). - RoHS 2011/65/CE Environmental standards: - WEEE 2012/19/EU - REACH (CE) regulation n. 1907/2006. - EN 60730-1 - IEC 60730-1. EMC standards: 115...
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 Digital inputs at 5 VDC mA (clean contact) Displays: Power: none. Protection: none. custom 3 digit display with decimal point and function icon. according to model, up to 6 outputs: - 2 SPST electromechanical relays with 30 A res. @ 250 VAC (compressor and evaporator fan) - 2 SPST electromechanical relays with 16 A res. @ 250 VAC (defrosting and room light) - 1 SPST electromechanical relay with 8 A res.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 EVBOX1 Front mounted electrical boards for cold rooms with single-phase compressor Installation guide ver. 1.3 PT - 30/14 Code 144BOX1E134 This document is exclusive property of EVCO; EVCO does not assume any liability regarding possible errors stated. The customer (manufacturer, installer or final user) assumes all liability regarding configuration of the device.
EVCO S.p.A. EVBOX1 | Installation guide ver. 1.3 | Code 144BOX1E134 EVCO S.p.A. Via Feltre 81, 32036 Sedico Belluno ITALY Phone 0437/8422 | Fax 0437/83648 info@evco.it | www.evco.