12.5 List of configuration parameters
The following table shows the meaning of the configuration parameters of the devices.
PARAM. MIN. MAX. M.U.
EVB1204
EVB1214
EVB1206
EVB1216
EVB1226
EVB1236
EVB1246
EVB1256
WORKING SETPOINT
SP r1 r2 °C/°F (1) -18.0 -18.0 -18.0 -18.0 -18.0 -18.0 -18.0 -18.0 Working set-point; see also r0
PARAM. MIN. MAX. M.U.
EVB1204
EVB1214
EVB1206
EVB1216
EVB1226
EVB1236
EVB1246
EVB1256
MEASUREMENT INPUTS
CA1 -25.0 25.0 °C/°F (1) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
if P4 = 0, 1, 2 o 3, room temperature offset
if P4 = 4, inlet air temperature offset
CA2 -25.0 25.0 °C/°F (1) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 evaporator temperature offset
CA3 -25.0 25.0 °C/°F (1) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 auxiliary temperature offset (see P4)
CA4 -25.0 25.0 °C/°F (1)
not
avail.
not
avail.
not
avail.
not
avail.
not
avail.
not
avail.
0.0 0.0 evaporation temperature offset
CA5 -25.0 25.0
points/10
(4)
not
avail.
not
avail.
not
avail.
not
avail.
not
avail.
not
avail.
0 0 vapour pressure offset
P0 0 2 - - - - 1 1 1 1 1 1 1 1
temperature probe type
0
=
PTC
1
=
NTC
2 = Pt 1000