Installer manual User Manual

EVCO S.p.A. EVXV 800 range | Installer manual ver. 1.2 | Code 144XV800E124
page 34 of 66
Par.
Min. Max. Unit
EVXV802
EVXV812
EVXV805
EVXV815
Analogue inputs
CA1 -25.0 25.0 °C/°F (1) 0.0 0.0 cabinet probe offset
CA2 -25.0 25.0 °C/°F (1) 0.0 0.0 needle probe offset
CA3 -25.0 25.0 °C/°F (1) 0.0 0.0 evaporator probe offset
CA4 -25.0 25.0 °C/°F (1) 0.0 0.0 condenser probe offset
P0 0 1 - - - - 0 0
probe type
0 = PTC
1 = NTC
P1 0 1 - - - - 1 1
°C decimal point
1 = yes
P2 0 1 - - - - 0 0
temperature unit of measurement (2)
0 = °C
1 = °F
P3 0 1 - - - - 1 1
enabling the needle probe
1 = yes
P4 0 1 - - - - 1 1
enabling the evaporator probe
1 = yes
P5 0 1 - - - - 1 1
fourth input function
0 = high pressure input (digital input)
1 = condenser probe (analogue input)
P8 0 250 ds 5 5
delay displaying temperature variation
detected by the probes
Par.
Min. Max. Unit
EVXV802
EVXV812
EVXV805
EVXV815
Main regulator
r0 0.1 15.0 °C/°F (1) 2.0 2.0
parameters differential r7, r8, r9, r10, r11
and r12
r1 1 500 min 90 90 duration of time-controlled blast chilling
r2 1 500 min 240 240 duration of time-controlled deep freezing