Installer manual User Manual
EVCO S.p.A. EVXV 800 range | Installer manual ver. 1.2 | Code 144XV800E124
page 38 of 66
C3 0 240 s 0 0 compressor switch-on minimum duration
C4 0 240 min 10 10
duration of compressor switch-off during the
cabinet probe error (“Pr1” code) that occurs
during storage; see also parameter C5
C5 0 240 min 10 10
duration of compressor switch-on during the
cabinet probe error (“Pr1” code) that occurs
during post blast chilling storage; also see
parameter C4
C6 0 199.0 °C/°F (1) 80.0 80.0
condenser temperature above which the
blocked overheated condenser alarm is
activated (“COH” code)
C7 0 199.0 °C/°F (1) 90.0 90.0
condenser temperature above which the
blocked compressor alarm is activated (“CSd”
code)
C8 0 15 min 1 1
blocked compressor alarm delay (“CSd” code)
(5)
C9 0 240 min 30 30
duration of compressor switch-on during the
cabinet probe error (“Pr1” code) that occurs
during post deep freezing storage; also see
parameter C4
Par.
Min. Max. Unit
EVXV802
EVXV812
EVXV805
EVXV815
Defrosting (6)
d0 0 99 h 8 8
defrosting interval (7)
0 = defrosting will never be activated at
intervals