Datasheet

ENERGY VERY ENDURE
ER14250
International size reference: 1/2AA
ELECTRICAL CHARACTERISTICS
(typical values for cells stored for one year or less, at 25 C)
echnical Specification
T
Note: Any representations in this data sheet concerning performance are for informational purpose only and are not construed as
warranties, either expressed or implied, of future performance.
Fire, explosion and severe burn hazard. Do not recharge, crush, disassemble,
heat above 100 C, incinerate, or expose contents to water.
WARNING:
Rated voltage
Nominal capacity
Maximum recommended continuous current
(at 1.0 mA, +25 C, 2.0V cut off. The capacity restored by the cell
varies according to current drain, temperature and cut off voltage.)
1.2Ah
3.6V
40mA
10g
11-08
Typical weight
(To get 50% of the nominal capacity at +25 C with 2.0V cut off.
Higher currents possible, consult EVE.)
Operating temperature range
-55 C / +85 C
(Operation at temperatur e different from ambient may lead
to reduced capacity and lower voltage plateau readings .)
Storage
30 C max
(recommended)
(for more severe condition consult EVE)
Lithium-thionyl Chloride
(Li-SOCl2) Battery
Pulse capability: Typically up to 100mA (100mA /0.1 second pulses,
drained every 2 min at 25 C from undischarged cells with 10μA base current,
yield voltage readings above 3.0 V. The readings may vary according to the
pulse characteristics, the temperature, and the cell's previous history. Fitting
cell with a capacitor may be recommended in severe conditions. consult EVE.)

Summary of content (2 pages)