Specifications

Even-GLO Series GA301 Page 26 Rev. 06/2009
Lighting and Shutdown Instructions
1. Lighting
a. Open manual gas supply valve (ensure gas supply lines have been
purged).
b. Turn on switch to energize electric supply.
c. The electronic control module will time out 45 sec.
d. The gas valve will open and ignition spark will commence and continue
for 15 sec.
e. If flame starts and “is detected”, flame will continue until turned off.
f. If flow does not start, the gas valve will close after 15 sec. A “wait’ period
commences and lasts about 30 sec. and a second trial for combustion
commences. The electronic control will attempt three trials for ignition
before locking out for about one hour at which time it will automatically try
again.
Electronic control of heater can be re-set by de-energizing and re-energizing electric
power.
2. Shut Down
a. Turn off power to electronic control.
b. For longer periods of shut down, also close manual gas supply valve.
alfresco-heating.com
888-Warm-Glo