Even-GLO Series GA301 Page 27 Rev. 06/2009
Maintenance and Trouble Shooting
Maintenance
Before performing any service shut off gas and electric supply.
Check condition of burner, especially integrity of flame screen.
Inspect condition of spark and sense electrode. Check for cracks in ceramic
insulators or excessive corrosion.
Inspect condition of high tension lead to spark rod.
Annually verify hose gas supply in heater post and all connections for gas
leaks.
Trouble Shooting
1. No gas supply at burner:
Ensure manual shut off valve is in proper position
Ensure there is pressure and flow at inlet to gas valve.
Ensure gas valve gets 24v power from control module during ON cycle.
2. No spark:
Ensure control module has 24VAC supply
Ensure spark electrode assembly is grounded and there are no cracks in
ceramic insulator.
3. Flame lights but will not stay lit:
Ensure there is no overpowering wind.
Ensure sense electrode is not corroded, is not grounded or has a cracked
insulator. Electrode position is radially across face of burner.
alfresco-heating.com