Manual

PitchFactor User Guide System Mode
49
To Assign the Control Source to a Destination
Press the Right Footswitch to select the MIDI Continuous Control that will be assigned to the
PitchFactor Control Source. The choices are:
OFF – Control Source unassigned.
C0 - C99 - MIDI Continuous Controller from 0 to 99.
Press the Left and Right Footswitches to toggle between Source and Destination to make as
many assignments as you wish.
Press the Middle Footswitch once to back-up one level to MIDI menu.
Press the Middle Footswitch twice to go to top level System menu.
[RCV MAP] – Create a MIDI Program Change Receive Map
MIDI maps are an efficient way to instantly recall any of PitchFactor’s Presets using your
favorite MIDI controller (pedal board, sequencer, etc.).
Press the Encoder to select and create a MIDI Program Change Receive Map. This function
sets the corresponding Preset that is recalled when a MIDI Program Change message is
received. (Referred to as Prg No. from here on.)
Note that if a Preset is saved “Bypassed,” when it is loaded by using a MIDI Program Change
command the Preset will load but the pedal will be Bypassed.
The left field displays the Prg No. (0-127) and right field displays either the Preset as
Bank:Preset (1:1-50:2), one of various Bypass options described below, or OFF.
There are two ways to select the MIDI Prg No: manually or using Learn Mode. To select
manually, with the left arrow flashing, simply turn the Encoder to select the desired Prg No.
from 0 to 127.
To use Learn Mode, press the Left Footswitch again. In LEARN mode, the Prg. No. will be
automatically set when a MIDI Program Change message is received. Pressing the Left
Footswitch exits LEARN mode.
Press the Right Footswitch to select the Bank Preset field (indicated by a flashing right hand
arrow) and turn the Encoder to select the Preset.
To map another Prg No. to another Preset, simply press the Left Footswitch again to select
the desired Prg No. and then the Right Footswitch to map it to the desired Preset.
Default map: Prg No. 0-99 map to the 100 Presets starting with Bank 1:1.
As well as using MIDI program change to load a preset, it can also be programmed to directly
control the unit’s BYPASS setting. When the flashing right hand arrow is visible, turn the
Encoder counter-clockwise to select one of the following:
BYP BYPass the unit
ACT Make the unit ACTive, i.e. not bypassed.
TOG TOGgle the between bypass and active.
Press the Middle Footswitch once to back-up one level to MIDI menu.
Press the Middle Footswitch twice to go to top level System menu.