Operator`s manual

Model VR240 Audio Logging Recorder
January 2000
3-19
a. After pressing the
Config
and
System
soft keys, press the
>
(next) soft key five times.
Then press the
DiskContrl
soft key.
b. Change your disk control setting as follows:
Change
Pressing the
Change
soft key toggles between the following two options:
Separate Hard Disk Control for each Drv
Automatic Disk Control (Public Safety)
Done
the hard disk control will be whatever is showing on the display when you
press the
Done
soft key.
Note: “Separate Hard Disk Control” is recommended when using the “Dual Record” feature.
3-21. AUTOMATIC RECORDING CONFIGURATION.
The VR240 has the capability of starting and stopping a recording automatically. You can set
the start time, stop time, and select a repeat cycle that will allow you, for instance, to record
every day between the hours of 08:00 and 17:30.
Once all the timers and parameters are set, pressing the
Enable
soft key locks the keyboard
and sets the unit to record as determined by the timers (see below). The only functions
available while in
AutoRec
are live monitor, media info, lock, and the ability to review the
autorecord settings. These functions are described in detail later on in this section. To regain
keyboard control and cancel the
AutoRec
operation, press the
(asterisk) key on the keypad.
Canceling
AutoRec
after enabling it also has the effect of resetting the timers. If you wish to re-
enter
AutoRec
, you must reset them.
a. Press the
Config
and then the
>
(next) soft key. Then press the
AutoRec
soft key.
Separate Hard Disk Control for each media
Change Done
AUTOMATIC RECORD CONFIGURATION:
< Enable SetTimers SetCycle Quit >