a. After pressing the
Config
and the
>
(next) soft key, press the
Board
soft key. Then
press the
VOX
soft key.
b. Press the
HoldTime
soft key.
Select the channel
for which the hold parameter is to be adjusted by pressing the
Channel
soft key. Its current value is shown on the upper line of the display.
Decrease and Increase soft keys
–increments the current delay setting by one second.
Incrementing above 255 seconds “wraps around” back to one second. Holding the
button down rapidly increments the delay.
Keypad entry
may be used to enter any number between 1 and 255, inclusive. Entering
an illegal value causes the delay time to remain as it was before the attempted
modification.
Enter
saves your parameter change for that channel. You must press this soft key each
time you make a change.
c. To save your setting or cancel this operation, press the
>
(next) soft key.
Save
drops back to the VOICE OPERATED SWITCHING menu and accepts all
the changes you have made to the individual channel holdoff times.
Cancel
drops back to the VOICE OPERATED SWITCHING menu and ignores any
changes you made to the holdoff times, leaving them as previously set.
VOICE OPERATED SWITCHING:
HoldTime
Level Quit
VOICE OPERATED SWITCHING:
HoldTime
Level
Quit