DUO II / DUO II Pro series UPS – Instruction Manual TABLE OF CONTENTS TABLE OF CONTENTS....................................................................................................................................... 2 INTRODUCTION ................................................................................................................................................. 3 GENERAL FEATURES OF THE UPS..................................................................................................
DUO II / DUO II Pro series UPS – Instruction Manual INTRODUCTION Thank you for purchasing the DUO II / DUO II Pro UPS. Please familiarise yourself with this instruction manual before you begin using the device. We hope that the purchased UPS will meet your expectations. EVER DUO II / DUO II Pro UPSs protect the devices connected to them from mains power losses, voltage drops and eliminate the danger of damages caused by overvoltage in the mains.
DUO II / DUO II Pro series UPS – Instruction Manual ELEMENTS OF THE UPS FRONT PANEL 1. Power switch 2. Operation mode indicator 3. Malfunction indicator REAR PANEL 1. 4 x IEC 320 outlet sockets 2. 10 A circuit breaker 3. Power lead 4. RJ telephone filter 5. Communication port (USB) – only DUO II Pro UPSs. 2010/03/19 www.ever.
DUO II / DUO II Pro series UPS – Instruction Manual SAFETY AND HEALTH INSTRUCTIONS HANDLING • exercise utmost caution when handling the device; • do not handle heavy equipment by yourself; • storage and operation of the device should take place in conditions conforming to its specification.
DUO II / DUO II Pro series UPS – Instruction Manual WARNING! DUO II / DUO II Pro UPSs were not designed to work with medical equipment, in particular life and/or health support devices. WARNING! Opening the casing may result in electric shock. WARNING! The UPS is disconnected from the mains only when the power lead is removed from the mains socket. INSTALLATION UNPACKING After unpacking, please inspect the device for damages.
DUO II / DUO II Pro series UPS – Instruction Manual CONNECTING THE UPS Due to the type and placement of cut-outs present in the UPS the safety circuits of the building function as one of the protection measures. This is essential to provide the UPS with shorting protection. The UPS may only be connected to a ~230V mains socket equipped with a grounding bolt. WARNING! After unpacking, place the device in the chosen spot without connecting the load (computer, monitor etc.
DUO II / DUO II Pro series UPS – Instruction Manual depends on the capacity of the internal batterry and the power of devices currently connected to the output (load). If the parameters of the mains voltage delivered to the UPSs input are correct, the battery will operate in the condition known as mains operation mode. While in the mains operation mode the input voltage is conducted to its output via the anti-overvoltage circuit.
DUO II / DUO II Pro series UPS – Instruction Manual SAFEGUARDS Against overloads The overload protection circuit indicates an overload in the mains operation mode at loads exceeding 110% of nominal power with a constantly lit up red LED and a continuous sound signal (DUO II 350/500) or with a flashing red LED and an intermittent sound signal (DUO II 800/1000). If this condition is maintained for a longer period of time, the UPS will switch off automatically.
DUO II / DUO II Pro series UPS – Instruction Manual COMMUNICATION BETWEEN THE UPS AND A COMPUTER DUO II Pro battery back-ups are equipped with a USB port enabling communication of the UPS with a computer. The device is supplied with a CD-ROM featuring the PowerSoft programme and a USB communication cable.
DUO II / DUO II Pro series UPS – Instruction Manual of the PowerSoft software (usually C:\Program Files\PowerSoft) to be searched. Next, the operating system will located and install the appropriate driver. In the case of Windows Vista the operating system will not initiate automatic installation of the drivers from the hard drive. After connecting the USB cable to the computer you will need to open the control panel from the Start Menu and select system properties.
DUO II / DUO II Pro series UPS – Instruction Manual dpkg –-remove powersoft FreeBSD For FreeBSD systems the software is provided in the form of the default package format designed for FreeBSD systems. The software is installed via the following command: pkg_add powersoftpersonal-x.x.x.
DUO II / DUO II Pro series UPS – Instruction Manual ADDITIONAL REMARKS WARNING! DUO II / DUO II Pro UPSs are designated as class C2. In domestic environment they may interfere with reception of radio waves so the user may be forced to implement additional preventive measures. WARNING! Inside the UPS there are no elements to be serviced by the end user. CUT-OUT The UPS is equipped with a resettable circuit breaker. While in normal operation mode of the UPS the breaker’s button should be pressed in.
DUO II / DUO II Pro series UPS – Instruction Manual WARNING! Do not connect LAN cables with RJ45 terminators because it may interrupt the transmission. STORAGE, MAINTENANCE AND TRANSPORT The UPS should be stored in a cool and dry place, in operating position, with batterries completely charged: • In temperature between 0°C and +30°C the batterry should be charged every 6 months; • In temperature between +30°C and +45°C the batterr y should be charged every 3 months.
DUO II / DUO II Pro series UPS – Instruction Manual TECHNICAL PARAMETERS PARAMETERS Output power Working environment Operating temperature Storage temperature Relative humidity for operation Relative humidity for storage Altitude (above sea level) Maximum length of outlet cables Duo II 350 Duo II 500 Duo II 800 Duo II 1000 Duo II Pro 350 Duo II Pro 500 Duo II Pro 800 Duo II Pro 1000 350VA / 210W 500VA / 300W 800VA/490W 1000VA/600W Office / industrial rooms with low level of pollution +10 ÷ +35 °C 0 ÷ +45
DUO II / DUO II Pro series UPS – Instruction Manual INFORMATION REGARDING REGULATIONS, WARRANTY AND SUPPORT DECLARATION OF CONFORMITY Manufactured in People's Republic of China. The UPSs structure conforms to the appropriate subject matter standards. WARRANTY A separate document attached to the product constitutes the warranty. The document must meet all formal requirements (e.g. the fields: serial number, model/type, date of sale, and dealer stamp must be filled out).