Pre-Delivery/Install Checklist

Submersible
Sump Pump
Quick Reference Guide
See instruction manual for
complete instructional details.
1. Ensure basin is clear of all debris and place pump
on hard level surface (not dirt or gravel). 18” x 24”
minimum basin size required.
2. Measure, cut and install discharge fittings, check
valve, and piping. Drill a 3/16” hole in the discharge
pipe, level with the top of the pump.
3. Plug Pump in to GFCI outlet on dedicated circuit with
15 amp breaker
4. Test operation by adding water until float rises, pump
turns on, and the water level drops. Float will lower
with the water level and turn the pump off.
5. Install optional basin cover.
EB-0053-rev 01/2022
GFCI Outlet
Check Valve
1-1/2” Discharge Pipe
1-1/2” Discharge Pipe
3/16” Vent Hole
18” Minimum
24” Minimum

Summary of content (1 pages)