SKU # 1001194470 Model # SW07501T USE AND CARE GUIDE SUBMERSIBLE SEWAGE PUMP Questions, problems, missing parts? Before returning to the store call Everbilt Customer Service 8 a.m. - 6 p.m., EST, Monday-Friday 1-844-241-5521 HOMEDEPOT.COM Rev. 05/20/17 THANK YOU We appreciate the trust and confidence you have placed in Everbilt through the purchase of this submersible sewage pump. We strive to continually create quality products designed to enhance your home.
Table of Contents Table of Contents .......................................................... 2 Performance .................................................................. 2 Safety Information ......................................................... 2 Warranty ......................................................................... 3 Pre-Installation .............................................................. 4 Installation .....................................................................
Safety Information (continued) CAUTION: Know the pump and its applications, limitations, and potential hazards. IMPORTANT: Ensure the electrical power source is adequate for the requirements of the pump. CAUTION: Secure the pump to a solid base. This will aid in keeping the pump in a vertical orientation. This is critical in keeping the pump operating at maximum efficiency. It will also help prevent the pump from clogging resulting in premature failure.
Pre-Installation APPLICATION This submersible sewage pump is designed for pumping sewage, effluent, wastewater or flooded water with up to 2 inch solids. TOOLS REQUIRED Flathead Screwdriver Phillips Screwdriver Hand Hacksaw or PVC Cutter Tape Measure Wrench Safety goggles Thread Tape MATERIALS REQUIRED (NOT INCLUDED) NOTE: Parts shown below not to scale. 2 in. discharge pipe 2 in. check valve 2 in. 90°elbow 2 in. adapter SPECIFICATIONS Power supply 115V, 60 HZ., 15 Amp Circuit Liquid temp.
Installation NOTE: Install pump on a hard, level surface (cement, asphalt, etc.). Never place the pump directly on earth, clay or gravel surfaces. In any case, piping must not be smaller than pump discharge. When installed in a sewage system, pipe must be capable of handling semisolids of at least 2 in. (5.1 cm) diameter. The rate of flow in the discharge pipe must keep any solids present in suspension in the fluid. To meet minimum flow requirements, the minimum pipe size is 2 in. Use a 2 in. (5.
Troubleshooting Problem Solution The pump fails to operate. 1. Check to be sure that the power cord is securely plugged into an outlet. Disconnect power to the outlet before handling the pump or motor. 2. Check to be sure you have electrical power. 3. Check that liquid fluid levels are high enough to activate the switch or controller. 4. Check to be sure that a 3/16 in. (4.7mm) vent hole in the discharge pipe is not plugged. 5.
Questions, problems, missing parts? Before returning to the store call Everbilt Customer Service 8 a.m. - 6 p.m., EST, Monday-Friday 1-844-241-5521 HOMEDEPOT.
SKU # 1001194470 Model # SW07501TC USE AND CARE GUIDE UPFLUSH SYSTEM Questions, problems, missing parts? Before returning to the store call Everbilt Customer Service 8 a.m. - 6 p.m., EST, Monday-Friday 1-844-241-5521 HOMEDEPOT.COM Rev. 04/20/17 THANK YOU We appreciate the trust and confidence you have placed in Everbilt through the purchase of this upflush system. We strive to continually create quality products designed to enhance your home.
Table of Contents Table of Contents .......................................................... 2 Performance .................................................................. 2 Safety Information ......................................................... 2 Warranty ......................................................................... 3 Pre-Installation .............................................................. 3 Installation .....................................................................
Warranty The manufacturer warrants the products to be free from defects in materials and workmanship for a period of one year from date of purchase. This warranty applies only to the original consumer purchaser and only to products used in normal use and service.
Pre-Installation(continued) Safety goggles Thread Tape Other necessary parts and tools may require: • Cloths, Rags • 2 in. PVC Close Nipple • 4 in. Expandable Plumber’s Plug • 2 in. 90° PVC Elbow • Hammer • 2 in. Slip Union • Hole Saw (3 in.) • 2 in. Slip x 3 in. NPT Reducer Bushing • Marker • Vent Pipe (see Step 14, Page 6) • Sponge • 5/16 in. Nut driver • Strap Wrench • 7/16 in. and 1/2 in.
Installation The upflush system can be installed as a free-standing unit or it can be enclosed. 1. Determine the location of the upflush system. Make sure you will have access to the existing discharge and vent lines. Make the necessary measurements, and determine the necessary fittings and piping that are required. Be sure to observe all local plumbing codes. 2. Put the tank in position. It must be level to within1/8 in. over its entire length.
Installation (continued) F. Insert the cords into the split cord grommet (see Repair Parts, Key No. 3), making sure that the cord grommet is right side up (see Figure 3) and outside the pump chamber. Leave yourself some slack in the cord. Figure 3: Cross-section of pump chamber lid and seals showing correct orientation of seals. G. Push the lid down into position on the pump chamber. Start bolts in the four corners of the lid to keep it in position on the pump chamber. H.
Installation (continued) 13. Assemble the union. Make sure that the elbow/check valve alignment with existing plumbing is correct. 14. Install a 2 in. or 3in.vent pipe (check your local plumbing code) in the 3 in.NPT threaded vent port on the pump chamber. You can use a 3 in. threaded pipe or glue the vent pipe to a male adapter (3 in. vent pipe)or 2 in. slip x 3 in.NPT reducer bushing (2 in. vent pipe),and then thread the assembly into the vent port on the pump chamber. 15.
Installation (continued) 22. Your local or state plumbing code may require you to test the system with a“10 ft. water column test”. If so, make certain the pump chamber lid screws are tightened down properly and that the lid gasket is seated. Plug the 4 in. diameter toilet opening (in the top of the tank) with an expandable plumber's plug (available at hardware stores). Also plug any other openings in the system except the highest one(normally the top of the vent stack).
Installation (continued) Figure 6:UpflushSystem Dimensions 9 For Professional Technical Support call 1-844-241-5521
Troubleshooting Troubleshooting information is for the pump only. WARNING: Risk of electrical shock. Always unplug the pump before handling it or making any adjustments. Always wear rubber boots when there is water on the floor and you must unplug the pump or make any adjustments. WARNING: Risk of infections from pathogens in pumped effluent. Wear rubber gloves when removing the pump from the tank and soak it in chlorine bleach for at least an hour before working on it or servicing it.
Troubleshooting (continued) Problem Solution The pump does not run. 1. The line fuse or circuit breaker may be off, blown or loose. 2. Water level in the tank may be too low to activate automatic float. 3. The power cord plug may not be making contact in the receptacle. 4. If all symptoms check OK, the motor is probably defective. Replace the pump. The pump runs but delivers no water or only a small amount of water. 1. The check valve may be installed backward.
Questions, problems, missing parts? Before returning to the store call Everbilt Customer Service 8 a.m. - 6 p.m., EST, Monday-Friday 1-844-241-5521 HOMEDEPOT.