Install Instructions

PRESS STOP VALVE
DOUBLE-O-RING
Instruction Manual
TECHNOLOGY
DO NOT PRESS
Copyright Everflow Supplies Inc. www.everflowsupplies.com
Inner Seal
PRESS HERE
PRESS OUTER
SEAL ONLY
Outer Seal
Note:
*Make sure copper pipe is deburred and free of gouges
1. Check seal for correct fit. Do not use oils or lubricants.
2. Mark proper insertion depth. Improper insertion depth
may result in improper seal.
3. While turning slightly, slide press end onto tubing to
mark the depth. End of tubing must contact stop.
4. Open the tool jaw and place at right angle on the valve.
Visually check insertion depth using mark on tubing.
5. Start pressing process and hold down until tool jaw
has engaged the press end. Only press outer ring.
6. After pressing, the jaw can be opened again.