User's Manual

53
Invalid Card
To disable a card, user can directly set the card as invalid card. An invalid card cannot
gain access to the system. At the same time, an Invalid Card event will be generated
when an invalid card is swiped on the reader. The default setting for Alarm Action
Setting and Extended Alarm Setting is: no alarm output is generated per invalid card
event, as shown in the following two figures, respectively. Change settings according
to sections “Enter Alarm Action Setting Sub-menu” and “Enter Extended Alarm
Setting Sub-menu”.
Invalid Door
Each card belongs to an access group. Each group has its own allowed doors and
time zones. That is, cards in the group have rights to pass which door at which time.
An Invalid Door event will be generated when a card is swiped at any door it does
not have right to pass. The default setting for Alarm Action Setting and Extended
Alarm Setting is: no alarm output is generated per invalid door event, as shown in the
following two figures, respectively. Change settings according to sections “Enter
Alarm Action Setting Sub-menu” and “Enter Extended Alarm Setting Sub-menu”.
Invalid Time
Each card belongs to an access group. Each group has its own allowed doors and
time zones. That is, cards in the group have rights to pass which door at which time.
An Invalid Time event will be generated when a card is swiped at any time it does not
have right to pass. The default setting for Alarm Action Setting and Extended Alarm
Setting is: no alarm output is generated per invalid time event, as shown in the
following two figures, respectively. Change settings according to sections “Enter
Alarm Action Setting Sub-menu” and “Enter Extended Alarm Setting Sub-menu”.
Card Anti-Passback Fail
For what is an Anti-Passback, please refer to section Anti-passback (APB) Setting in
this chapter. A Card Anti-Passback Fail event will be generated when the APB
property of a card is set as enabled and that card is swiped twice consecutively on any
enter-door reader or exit-door reader. The default setting for Alarm Action Setting
Invalid Time
NNNNNNNN
Invalid Time
NNNNNNNN-NN
Invalid Door
NNNNNNNN
Invalid Door
NNNNNNNN-NN
Invalid Card
NNNNNNNN-NN
Invalid Card
NNNNNNNN
Expired Card
NNNNNNNN
Expired Card
NNNNNNNN-NN